Storage; Engine Storage; Generator Storage - Champion Power Equipment C71350E Manual

Table of Contents

Advertisement

Storage

Storage
The generator should be started at least once
every 14 days and allowed to run for at least
20 minutes. For longer term storage, please
follow these guidelines.

Engine Storage

1.
Allow the engine to cool completely
before storage.
2. Clean the engine according to the
instructions in the Maintenance section.
3. Turn off the fuel valve on the generator.
4. Close the manual shutoff valve on the
LPG cylinder and disconnect from the
generator.
16
5. Change the oil.
6. Remove the spark plug and pour about
½ ounce of oil into the cylinder. Crank
the engine slowly to distribute the oil
and lubricate the cylinder.
7. Reattach the spark plug.

Generator Storage

1.
Allow the generator to cool completely
before storage.
2. Turn off the fuel supply at the fuel valve.
3. Clean the generator according to the
instructions in the Maintenance section.
4. Store the unit in a clean, dry area, out of
direct sunlight.

Advertisement

Table of Contents
loading

Table of Contents