(b) Execute-Disable Bit Capability
Selects the function to reports whether the CPU Execute-Disable Bit is
available or not to OS. When the CMOS is damaged, the default is Available.
When Home is pressed, the setting is not changed and the setting is kept.
Available
Not Available
(c) Auto Power On
Use this option to set a time and date for automatic power on and enable or
disable the ring indicator feature. Alarm Date Option appears only when
Alarm Time is enabled.
Alarm Time
Alarm Date Option
Wake-up on LAN
*Only for LAN Model
Alarm Time is set in the sequence of hours and minutes. Seconds cannot be
changed. Alarm Date Option is set in the sequence of month and day. If
Alarm Date is set to Disabled, the computer will be powered on at the same
time every day. Press ↓ to move the cursor to the right and ↑ to move the
cursor to the left when you set the date and time.
NOTE: 1. Do not remove the AC adapter and battery pack at the same time when you use
this feature. If you do so, data saved by the resume function will be lost. You
must also reset this option.
2. When a password is set in Password Security, the system is in standby mode,
the Timer on function (Auto Power PN) is set and the system is booted,
"Password =" is displayed. When the password set in Password Security is
input, the computer returns to Windows from standby mode.
3. This function is effective only once, it is released after booting up.
PORTEGE R300 Maintenance Manual (960-591)
All manuals and user guides at all-guides.com
Reports that the function is available.
Reports that the function is not available. (Default)
OPTIONS
3 Tests and Diagnostics
= 00:00:00
= Disabled
= Disabled*