10 Preload, Deadload and Overload settings

max. Preload* (kg)
Kern model
* = additional initial load
KXP 600V20SM
KXP 600V20M
KXP 1500V20SM
KXP 1500V20M
KXP 3000V20M
1500kg
Platform type
Platform dimension
(mm)
KXP 600V20SM
1000x1000x80
KXP 600V20M
1500x1250x80
1000x1000x80
KXP 1500V20SM
KXP 1500V20M
1500x1250x80
KXP 3000V20M
1500x1250x80
18
Deadload** (kg)
**= already applied
preload
300kg
90
300kg
120
750kg
90
750kg
120
120
Loadcell
TC
Type
No.
CZL-8C-0.5T
D09-03.19
CZL-8C-0.5T
D09-03.19
CZL-8C-1T
D09-03.19
CZL-8C-1T
D09-03.19
CZL-8C-1.5T
D09-03.19
Center Overload
Protection circa
(kg)
NA
NA
NA
NA
NA
Class
Max
E
E
max
min
Preload
-1
-4
(kg)
(kg)
(g)
C3
300
500
0
C3
300
500
0
C3
750
1000
0
C3
750
1000
0
C3
1500
1500
0
Corner Overload
Loadcell
Protection circa
Capacity (kg)
(kg)
N/A
N/A
N/A
N/A
N/A
Y
n
Dead-load
T
-3
(kg)
-5
300kg
10000
3000
300kg
10000
3000
750kg
10000
3000
750kg
10000
3000
1500kg
10000
3000
KXP V20_600-3000-IA-e-1511
500kg
500kg
1000kg
1000kg
1500kg
T
Cable-
min
max
length
-6
(m)
-10
40
5
-10
40
5
-10
40
5
-10
40
5
-10
40
5

Advertisement

Table of Contents
loading

Table of Contents