Deadload And Overload Settings - KERN KFP-V20NM Installation Instructions Manual

Floor scale
Table of Contents

Advertisement

10 Deadload and Overload settings

max. Preload* (kg)
Kern model
* = additional initial load
KFP 600V20SNM
KFP 600V20NM
KFP 1500V20SNM
KFP 1500V20NM
KFP 3000V20NM
KFP 3000V20LNM
Platform type
Platform
dimension (mm)
KFP 600V20SNM
1000x1000x80
KFP 600V20NM
1500x1250x80
KFP 1500V20SNM
1000x1000x80
KFP 1500V20NM
1500x1250x80
KFP 3000V20NM
1500x1250x80
KFP 3000V20LNM
1500x1500x80
18
Center Overload
Protection circa (kg)
90
NA
120
NA
90
NA
120
NA
120
NA
150
NA
Loadcell
TC
Class
Type
No.
CZL-8C-0.5T
D09-03.19
CZL-8C-0.5T
D09-03.19
CZL-8C-1T
D09-03.19
CZL-8C-1T
D09-03.19
CZL-8C-1.5T
D09-03.19
CZL-8C-1.5T
D09-03.19
Corner Overload
Protection circa (kg)
N/A
N/A
N/A
N/A
N/A
N/A
E
E
Y
max
min
-1
-4
(kg)
(g)
C3
500
0
10000
C3
500
0
10000
C3
1000
0
10000
C3
1000
0
10000
C3
1500
0
10000
C3
1500
0
10000
Loadcell
Capacity (kg)
500kg
500kg
1000kg
1000kg
1500kg
1500kg
n
Dead-load
T
T
min
max
-3
(kg)
-5
-6
90kg
3000
-10
40
120kg
3000
-10
40
90kg
3000
-10
40
120kg
3000
-10
40
120kg
3000
-10
40
150kg
3000
-10
40
KFP V20NM-IA-e-1511
Cable-
length
(m)
5
5
5
5
5
5

Advertisement

Table of Contents
loading

Table of Contents