LCD display
15 : OUTPUT-R (-12dB)
Checks each output level from the R channel of the jacks.
1) Connect the level meter to an output jack.
2) Set the [MASTER VOLUME] control to the maximum position.
3) Press the [ENTER] button to produce the 1kHz sine wave sound. "ON" is shown on the LCD.
4) Measure the output level and confirm that the measured values are within the specified range.
-ohms
[PHONES] (33
load)
PHONES L: -60 dBu or less
PHONES R: -6.5 dBu±2 dB
[OUTPUT (Balanced)] (600
OUTPUT L/MONO (HOT/COLD): -90 dBu or less
OUTPUT R (HOT/COLD): +2.7 dBu±2 dB
[ASSIGNABLE OUTPUT (Balanced)] (600
OUTPUT L (HOT/COLD): -90 dBu or less
OUTPUT R (HOT/COLD): +2.7 dBu±2 dB
Distortion rate
All output terminal R: 0.1 % or less
5) Set the [MASTER VOLUME] control to the minimum position.
6) Measure the output level and confirm that the measured values are within the specified range.
[OUTPUT (Balanced)] (600
OUTPUT R (HOT/COLD): -73 dBu or less
7) Press the [EXIT] button, and testing is finished and the display is changed to the test item selection
screen.
Test items and judging conditions
-ohms
load)
-ohms
load)
-ohms
load)
MONTAGE6/MONTAGE7
63