Aem Accuracy And Performance; Usage - Silicon Laboratories SLWSTK6104A User Manual

Mgm220p wireless gecko module starter kit
Table of Contents

Advertisement

UG461: MGM220P Wireless Gecko Module Starter Kit User's Guide
Advanced Energy Monitor

7.3 AEM Accuracy and Performance

The AEM is capable of measuring currents in the range of 0.1 µA to 95 mA. For currents above 250 µA, the AEM is accurate within 0.1
mA. When measuring currents below 250 µA, the accuracy increases to 1 µA. Even though the absolute accuracy is 1 µA in the sub
250 µA range, the AEM can detect changes in the current consumption as small as 100 nA.
The AEM current sampling rate is 10 kHz.
Note: The AEM circuitry only works when the kit is powered and the power switch is in the AEM position.

7.4 Usage

The AEM data is collected by the board controller and can be displayed by the Energy Profiler, available through Simplicity Studio. By
using the Energy Profiler, current consumption and voltage can be measured and linked to the actual code running on the MGM220P in
realtime.
silabs.com | Building a more connected world.