Minimum Framing Clearances - Urbana U30I-S Installation Manual

Table of Contents

Advertisement

Minimum Framing Clearances

7" Min.
Side Wall
Clearance
Beside
Fireplace
U30 65" Min.
U30T 71 5/8" Min.
Chase
Height
1
1
2 " Min.
Side Wall
Clearance
In Front Of
Fireplace
Minimum Framing Clearances
All framing may be wood 2X4 construction or the like, no steel stud or concrete board required.
Using wood framing is a result of meticulous design and testing practices. We ask that the restrictions be followed in order
for the fireplace to be enjoyed safely.
NOTES:
• Chase may be framed beyond minimum framing for taller ceilings, overhangs etc.
• Chase cannot be open to joists or rafters above.
• Chase heat release(s) must be at least 60" (152 cm) away from the nearest fire sprinkler head.
• The fireplace is not load bearing so the chase must be constructed to fully support finishing materials.
• Less restricted air flow will always breathe more efficiently maintaining cooler surface temperatures.
• No intake air gap is required
The following diagrams are common ways to frame your fireplace. Other forms can also be used as long as minimum
clearances and air gaps are maintained. Use the diagrams and table on the following page as a baseline to design your
enclosure. Framing illustrations are for example only and are not necessarily meant to be followed exactly.
26 |
IMPORTANT NOTE: Framing above the fireplace CANNOT be
constructed prior to fireplace installation, the fireplace and
2" Min. Heat Release Opening
120in sq. Min.
3
30
4 "
1 1/2" Min. Intake Opening
90in sq. Min.
Framing and Installation
it's required shielding WILL NOT FIT!
Min. Vent: 4X6 5/8
Ceiling Clearance
12" Up + 90deg Elbow
5" Max.
Recess
Depth
13" Min. to
Recess
Underside
21" Min.
12" Max. Finished
Plinthe Depth
6" First Elbow to
18" Min.
Clearance
Overhang
U30 56" Min.
U30T 62 5/8" Min.
Vent
Install
Height
Depth

Advertisement

Table of Contents
loading

Table of Contents