Minimum Framing Clearances - Urbana U50I-S Installation Manual

Table of Contents

Advertisement

Minimum Framing Clearances

2" Min. Height Heat Release Opening [Front & Sides]
[U70I-S = 210 sq. in. Min. open area]
[U50I-S = 170 sq. in. Min. Open area]
7" Min.
Sidewall
Clearance
Beside
Fireplace
Minimum Framing Clearances
All framing may be wood 2X4 construction or the like, no steel stud or concrete board required.
Using wood framing is a result of meticulous design and testing practices. We ask that the restrictions be followed in order
for the fireplace to be enjoyed safely.
NOTES:
• Chase may be framed beyond minimum framing for taller ceilings, overhangs etc.
• Chase cannot be open to joists or rafters above.
• Chase heat release(s) must be at least 60" (152 cm) away from the nearest fire sprinkler head.
• The fireplace is not load bearing so the chase must be constructed to fully support finishing materials.
• Less restricted air flow will always breathe more efficiently maintaining cooler surface temperatures.
• No intake air gap is required
The following diagrams are common ways to frame your fireplace. Other forms can also be used as long as minimum
clearances and air gaps are maintained. Use the diagrams and table on the following page as a baseline to design your
enclosure. Framing illustrations are for example only and are not necessarily meant to be followed exactly.
26 |
Framing Width
U50I-S = 50 3/4"
U50I-S = 70 3/4"
IMPORTANT NOTE: Framing above the fireplace CANNOT be
constructed prior to fireplace installation, the fireplace and
it's required shielding WILL NOT FIT!
5" Max. Framed
Recess Depth
U50I-S / U70I-S
88 1/2" Min.
Chase
Ceiling
12" Max. Depth
U50I-S/U70I-S
37"
Overhang / Mantle @ 0"
Framed
Opening
12" Max.Finished
Height
Plinthe Depth
Framing and Installation
Termination Sidewall
Clearance = 12"
4 3/4" Min.
Ceiling to Elbow
Clearance
Min Vent [5x8] =
3' up + 90º Elbow
20" Min.
Framed Recess
Height
24" Min.
Overhang
Clearance
1 1/2"
Termination
Standoff
U50I-S / U70I-S
79 3/4"
21" Min.
Min. Vent
Framing
Height
Depth

Advertisement