Panasonic PT-DZ13KU Service Manual page 19

3-chip dlp based projector
Hide thumbs Also See for PT-DZ13KU:
Table of Contents

Advertisement

5. SELF CHECK
Self-diagnosing information Displays.
Main microprocessor Software Version
Sub microprocessor Software Version
Network microprocessor Software Version rootfs/kernel
Ballast microprocessor Software Version
Intake air temperature check (Celsius/Fahrenheit)
DMD temperature check (Celsius/Fahrenheit)
Exhaust air temperature check (Celsius/Fahrenheit)
Airflow sensor check (Sensor value/AD conversion value/Correction value)
LAMP1 check (Cumulative usage time/ON-OFF)
LAMP2 check (Cumulative usage time/ON-OFF)
Fan check (1: normal /0:stop)
Brightness sensor check
Angle sensor check
Iris check
6. POWER OFF MESSAGE
Setting of the shutter function with standby operation
- SHUTTER KEEP: When push the standby key with shutter ON, keep the shutter mode.
- SHUTTER OPEN: When push the standby key with shutter ON, open the shutter and display
the "Power OFF confirmation message". (Default setting)
7. ERROR OSD
When do not watch the error instructions LED of the lamp by a back projection,
the errors of the lamp can be displayed in the OSD.
- ON: "Lamp error message" is displayed on OSD.
- OFF: Does not display the "Lamp error message" in OSD.
8. CONVERGENCE
When the ingredient of each R/G/B color deviation, revise it electrically.
Specifically, please refer to Clause 1 of SECTION 3 (adjustments).
9. MODEL
Set this when the A-P.C.Board is replaced.
* If you can copy EEPROM data from the old A-P.C.Board, this setting is unnecessary.
* This model setting is changed after power restart.
SELF CHECK
Y
* If any error occurs, font of "OK" becomes red.
OK FAN
1 1 1 1
1 1 1 1
1 1 1 1
1