  • Page 1 GUIDE...
  • Page 2 AND ANY INFORMATION CONTAINED ment (EULA), a copy of which can be found HEREIN, INCLUDING BUT NOT LIMITED TO at http://www.keysight.com/find/sweula. THE IMPLIED WARRANTIES OF The license set forth in the EULA represents Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 3: Table Of Contents

    Rear panel 1 Getting Started Unpacking the Lightwave Component Analyzer Setting Up the Lightwave Component Analyzer Using the correct connectors Enabling and disabling the laser output Starting the LCA Accessing the User’s Guide Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 5: Introduction

    Keysight N4376E Lightwave Component Analyzer Getting Started Guide Introduction Documentation General Safety Considerations Optical Test Set Front and Rear Panels / 14...
  • Page 6: Documentation

    Introduction Documentation The documentation for the Keysight N4376E Lightwave Component Analyzer consists of • The documentation for the Keysight network analyzer. This documentation is on the hard disk of the network analyzer. Refer to it for using the network analyzer for electrical to electrical measurements, or for the configuration of the network analyzer.
  • Page 7: General Safety Considerations

    The laser radiation symbol. This warning symbol is marked on products which have a laser output. The Off-On symbols are used to mark the positions of the instrument power operating switch. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 8 Any interruption of the protective conductor inside or outside of the instrument is likely to make the instrument dangerous. Intentional interruption is prohibited. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 9 Always use the three-prong AC power cord supplied with this CAUTION instrument. Failure to ensure adequate earth grounding by not using this cord may cause instrument damage. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 10: Initial Safety Information

    IEC 60825-1 we recommend that you stick the laser safety labels, in your language, onto a suitable location on the outside of the instrument where they are clearly visible to anyone using the instrument. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 11 The laser is on when the green LED above the button is lit. • The use of the instruments with this product will increase the eye hazard. • Refer servicing only to qualified and authorized personnel Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 12: Line Power Requirements

    Introduction Line power requirements The Keysight N4376E Lightwave Component Analyzer complies with CAUTION over-voltage category II and can operate from the single-phase AC power source that supplies between 100 V and 240 V at a frequency in the range 50 to 60 Hz. The maximum power consumption of the optical test set is 40 VA with all options installed.
  • Page 13: Environmental Information

    Directive Annex I, this product is classed as a "Monitoring and Control instrumentation" product. Do not dispose in domestic household waste. To return unwanted products, contact your local Keysight office, or see about http://about.keysight.com/en/companyinfo/environment/tak eback.shtml for more information. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 14: Optical Test Set Front And Rear Panels

    2-port PNA version Figure 2 Front Panel for 2-port PNA (Options 22x) For further information on the front panel of the network analyzer, please refer to the documentation supplied with the network analyzer. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 15 This input is the standard optical input to the optical test set for optical powers up to 0 dBm. Port B This is the RF port used for electrical calibration and to connect to O/E and E/E devices. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 16 • : Perform continuous sweep measurements with the current measurement setup • : Start the optical power meter • : Start the LCA server (if not already running) Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 17: 4-Port Pna Version

    4-port PNA version Figure 3 Front Panel for 4-port PNA (Options 42x) For further information on the front panel of the network analyzer, please refer to the documentation supplied with the network analyzer. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 18 This input is the standard optical input to the optical test set for optical powers up to 0 dBm. Port B This is the RF port used for electrical calibration and to connect to O/E and E/E devices. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 19 Network analyzer Port 2 This is an S parameter measurement port of the Network analyzer. This is the RF port used for electrical calibration and to connect to differential EO, OE and EE devices. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 20: Rear Panel

    USB port to control the optical test set. External Input Plug in an external laser source. Line power cable Plug in your power cable here. connector Line fuse Replace only with same type. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 21: Getting Started

    Keysight N4376E Lightwave Component Analyzer Getting Started Guide Getting Started Unpacking the Lightwave Component Analyzer / 22 Setting Up the Lightwave Component Analyzer / 24...
  • Page 22: Unpacking The Lightwave Component Analyzer

    1x 0960-2819 LC-LC adapter • 2x N4373-87954 LC 62.5 μm to FC/APC 0.5 m patch cord • -025: • 1x 1005-1264 SC-SC adapter • 2x N4373-87950 SC 50 μm to FC/APC 0.5 m patch cord Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 23 Integration of customer’s 26.5 GHz, 4 port PNA (N5222A or N5242A) with any configuration and RF cables If anything is missing or defective, contact your nearest Keysight Technologies sales office. If the shipment was damaged, contact the carrier, then contact the nearest Keysight Technologies sales office.
  • Page 24: Setting Up The Lightwave Component Analyzer

    (red) and angled (green) connectors, make sure you connect the angled connector to the optical test set. Connecting to the optical test set with a straight connector will damage Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 25 On the rear, using the USB cable supplied, connect the network analyzer to the optical test set. Connect the power cables. We recommend you backup your LCA data regularly. Please refer to NOTE “User’s Guide” for information on the files to backup. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 26: Using The Correct Connectors

    The optical input and output of the Keysight N4376E Lightwave Component Analyzer use angled connectors. Depending on the option you ordered, you will also have received one or two patchcords with an angled and a straight connector.
  • Page 27: Enabling And Disabling The Laser Output

    If the LCA server is running, but the function keys are not displayed, press the [Macro/Local] Utility key until they appear. Press You can now proceed with setting up a measurement. For further information on measurements, refer to the User’s Guide. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...
  • Page 28: Accessing The User's Guide

    Accessing the User’s Guide If it is not already started, start the LCA as described above. Press in the LCA user interface to get to the electronic version of the User’s Guide. Keysight N4376E Lightwave Component Analyzer Getting Started Guide...