Advertisement

Quick Links

Herkules XL S120
Herkules XL S120 vapor
Herkules XL S120 vapor
Assembly and operating instruction
GB
MADE IN GERMANY
IPx4
Druck Nr. 29343553en
/22.10
D
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Herkules XL S120 and is the answer not in the manual?

Questions and answers

Summary of Contents for EOS Herkules XL S120

  • Page 1 Herkules XL S120 Herkules XL S120 vapor Herkules XL S120 vapor Assembly and operating instruction MADE IN GERMANY IPx4 Druck Nr. 29343553en /22.10...
  • Page 2: Table Of Contents

    Positioning of sensor ..................7 Installation .......................8 Electrical connection .....................10 Herkules XL S120 18 kW ................10 Herkules XL S120 vapor 18 kW ..............11 Herkules XL S120 24 kW ................12 Herkules XL S120 vapor 24 kW ..............13 Herkules XL S120 30 kW ................14 Herkules XL S120 vapor 30 kW ..............15...
  • Page 3: Intended Use

    Dear Customer, For installation and electrical connection of the rocker switch follow the installation in- You have purchased a high quality technical structions supplied with this part. system which will provide you with many ye- ars of enjoyable sauna bathing. This sauna heating system was constructed in accor- General notes dance with state-of-the-art European safety...
  • Page 4: Important Notes

    Important notes air intake and exhaust vents must not be closed. Please observe the information If assembled incorrectly, the sys- provided by your sauna cabin supplier. tem will present a fi re hazard. • For the adjustment and control of the sau- Please read this installation guide tho- na heating unit, one of the control units roughly.
  • Page 5: Electrical Connection

    in the table. Electrical connection • During the installation of the sauna hea- Your electrician will be able to accomplish ting unit, make certain that the vertical this work without further explanation in ac- cordance with the provided wiring schematic clearance between the upper edge of the and with the help of the circuit diagram sauna heating unit and the sauna ceiling...
  • Page 6 2 x 60 kg LSG 18 EMOTEC HCS 9003 EMOTEC HCS 9003 DB/DL/DLF EmoTouch II PB/AF/GF 30 kW 45 - 65 m³ 50 x 10 cm LSG 36 Herkules XL S120 vapor Connecting Connecting Connecting Connecting Connecting Capacity Electrical. Fuse control...
  • Page 7: Installation

    Installation • The clearance between infl ammable mate- rials and the sauna heater must be at least Caution: remove the side panes 8 cm. for transporting without a euro • The wooden rail is no substitute for a safe- pallet!!! ty barrier for protection against accidental (It is not possible to carry the sauna heater contact.
  • Page 8: Installation

    Screw the connection hose of the vapori- zing bowl to the bottom fi tting of the water level control (only Herkules XL S120 vapor) A plunger (1) opens or closes the volve (2), so that you can be sure your container is al- ways full.
  • Page 9 Heizstab-Verdampfer zum Steuergerät 9 kW heating element water to control unit max. 1,5 kW zum Leistungsschaltgerät 9 kW to power control unit 18 kW max. 1,5 kW Thermostat- Verdampfer Summer 5 4 3 2 1 3 2 1 buzzer Thermal cut-out Anschluß...
  • Page 10: Electrical Connection

    Electrical connection Caution! Always include the Herkules XL S120 18 kW neutral line N in the connec- tion...
  • Page 11: Herkules Xl S120 Vapor 18 Kw

    Herkules XL S120 vapor 18 kW Caution! Always include the neutral line N in the connec- tion...
  • Page 12: Herkules Xl S120 24 Kw

    Herkules XL S120 24 kW Caution! Always include the neutral line N in the connec- tion...
  • Page 13: Herkules Xl S120 Vapor 24 Kw

    Herkules XL S120 vapor 24 kW Caution! Always include the neutral line N in the connec- tion...
  • Page 14: Herkules Xl S120 30 Kw

    Herkules XL S120 30 kW Caution! Always include the neutral line N in the connec- tion...
  • Page 15: Herkules Xl S120 Vapor 30 Kw

    Herkules XL S120 vapor 30 kW Caution! Always include the neutral line N in the connec- tion...
  • Page 16: The Water Connection

    The water connection De-scaling of the vaporizer (only Herkules XL S120 vapor) Attention! The sauna heater must be connected with At all cleaning- and maintenance the water main supply at the installation jobs, by changing of parties or accesso- site...
  • Page 17: Assembly Of The Protective Cover On The Sauna Heater

    Assembly of the protective cover on the sauna heater All plate screws for suspension of the heater protector. All metric screws: for mounting the rocker switch All dimensions provided in mm. 4 plate screws for each 94 4711 je 4x Ø 3,5 Control cable for rocker switch Lay the control cable for the rocker switch and heater...
  • Page 18: Finnish Sauna Operation

    Finnish sauna operation Operation with vaporizer For this type of operation, the vaporizer is not (only Herkules XL S120 vapor) used. It is very important to make sure that no The control of the vaporizer is managed herbs or essences are present in the herbal by the control unit.
  • Page 19: Sauna Stones

    Sauna stones Maintenance and care The sauna stone is a natural product. Check All sauna heating units are made of low- the sauna stones at regular intervals. Strong corrosion material. Still, to enjoy your sau- infusion concentrates especially can wea- na heating unit for a long time, you should ken the sauna stones and cause them to maintain and care for the unit.
  • Page 20 For the installation of sauna heaters, please pay attention to the DIN VDE 0100 part 703 ! This standard makes the following statement valid in your newest expenditure, since Febru- ary 2006, paragraph 703.412.05; Quotation: The additional must be planned for all electric cir- cuits of the Sauna by one or more fault current protection device (RCDs) with a calculation diffe- rence stream not more largely than 30 mA, exclu-...
  • Page 21: Service Address

    Service Address: Outside of Germany please contact your EOS-WERKE GÜNTHER GmbH specialist dealer in case of warranty claims. Adolf-Weiß-Straße 43 Direct warranty processing with our service 35759 Driedorf-Mademühlen, Germany department is in this case not possible.
  • Page 22: Handling Procedures For Return Shipments (Rma) - Details For All Returns

    Handling procedures for return shipments (RMA) - Details for all returns ! Dear customer we hope that you will rejoice in the ordered articles. Just in case that you are not entirely contented as an exeption, please follow the procedures specified below.This enabling us to ensure a quick and smooth handling of the return shipment.

This manual is also suitable for:

Herkules xl s120 vapor