6.1.3.7 Indoor fan control
Use the remote controller to set the indoor fan running at HIGH, MED or LOW speed. At this time the fan will run
at high, medium or low speed. It can also be set to AUTO and the indoor fan will select fan speed(HIGH, MED or
LOW) automatically according to ambient temperature.
There are at least 3mins and 30s delay for fan speed shift.
6.1.3.8 Power supply for outdoor unit
The power supply for outdoor unit is turned on in AUTO, COOL, HEAT and DRY mode under turn-on state.
The power supply for outdoor unit will delay 3 minutes to turn off under turn-off state or in the FAN mode under
turn-on state.
6.1.3.9 Swing control
Use the SWING button of the wireless remote control to control SWING On and Off. Swing will only act when
indoor fan is running.After power on, the swing motor turns back to 0 position and closes the air outlet vent; if it
does not preset swing, after the unit is turned on, it will turn to the max. air outlet D1 position; then turn back to L
position under COOL mode.Under HEAT mode,the guide louver stays at D1;when in swinging state, it will swing
between L1 and D1 position. When the unit is turned off, it will turn back to 0 position.
6.1.3.10 Buzzer control
When the unit is power on or receives remote control signal or the auto key be pressed,the buzzer will give out a beep.
6.1.3.11 Power-off memory function
Contents of memory: Mode; Swing; Set fan speed, Set temperature,Timing etc.
Under turn-on state, when power off and power on, the power supply for outdoor unit will be turn on after 3mins .
Under turn-off state, when power off and power on, the power supply for outdoor unit will be turn on immediately.
6.1.3.12 Delay Protection of Compressor
Under COOL; DRY; HEAT mode, before each time the compressor starts, there will be 3mins delay.
6.1.4. Common protection function in each mode
6.1.4.1 Overload protection
T
:at cooling,it detects the temp. of outdoor heat exchanger,at heating,it detects the temp. of indoor heat exchanger.
tube
When Ttube is detected high, the compressor will run in limited frequency.When Ttube goes on rising over the stated
value, the compressor will stop, under AUTO HEAT or HEAT mode, indoor fan will blow 60s at low fan speed and
then stop, under other mode, the indoor fan will run at set speed.
6.1.4.2 Compressor discharge temperature protection
When discharge temperature is too high to over the stated value, the compressor will stop, and When discharge temp.
resume normal and the compressor has stopped for 3 minutes, the unit will resume its original operating status.
6.1.4.3 Communication malfunction
When not receiving correct signal for 3 minutes, the unit has communication malfunction and the outdoor unit
stops, it is the same as normal stop when meeting the set temp..
6.1.4.4 Module protection
When module is in protection, the compressor will stop, after the compressor has stopped for 3 minutes, it will
resume to running. During module protection period, the indoor unit displays malfunction and the whole unit stops.