Soleus Air KFHHP-18-ID Operating And Installation Manual

Soleus Air KFHHP-18-ID Operating And Installation Manual

Wall mounted mini split heat pump air conditioner

Advertisement

Wall Mounted Mini Split
Heat Pump
Air Conditioner
OPERATING AND INSTALLATION MANUAL
Model: KFHHP-18-ID / KFHHP-18-OD
Indoor Unit.
Outdoor Unit.
Thank you for selecting Soleus Air. To ensure proper
operation, please read this manual and keep it for
future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KFHHP-18-ID and is the answer not in the manual?

Questions and answers

Summary of Contents for Soleus Air KFHHP-18-ID

  • Page 1 Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFHHP-18-ID / KFHHP-18-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference.
  • Page 2: Table Of Contents

    Electrical Schematic Diagram (Indoor Unit)…………………………...……………...………….22 Electrical Schematic Diagram (Outdoor Unit)………..……………………….……………………23 WARRANTY…………………………………………………………………………………………24 Danger Caution. Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference. TABLE OF CONTENTS This mark indicates a direction/procedure that...
  • Page 3: Use And Maintenance

    ★There is a possibility of electric shock or fire. To avoid electric shock or fire, use an approved circuit. ★Please turn off the power before cleaning the air conditioner. cut off the power Use and Maintenance Warning To avoid electric shock.
  • Page 4: Precautions On Use

    ◆Precautions on Use Grounding: The unit must be ★ properly grounded. ★Close all doors & windows for efficient operation. ★To avoid damage make sure the mounting of the unit is secure. ★Set the room temperature appropriately. The difference between indoor and outdoor temperature shall be 40 °F.
  • Page 5 ◆Precautions on Use ★Adjust the air flow and direction properly. When the air conditioner is running, you can press the SWING key on the remote control to adjust the guide louver and change the direction of air flow. ★To avoid injury or damage, never stick your fingers or any other object into the unit.
  • Page 6: Specifications And Technical Data

    (44.6°F /-, 75.2°F /69.8°F). Working temperature range Maximum cooling Minimum cooling Maximum heating Minimum heating KFHHP-18-ID / KFHHP-18-OD 18000 / 5300 (1400-6000) 20000 / 6000 (1100-7000) Indoor unit :40.16” × 8.98” ×12.20” Outdoor unit:37.40” × 13.39” × 26.93” 26.25 0.21...
  • Page 7: Instructions For Use

    When the outdoor temperature is low but the humidity is high, the heat exchanger of outdoor unit may freeze * after the air conditioner has run for a period of time. This will decrease the heating effect. In this case, auto defrost function will be activated and the heating mode will temporarily stopped for 8-10 minutes.
  • Page 8: Description Of Air Conditioner Components

    ◆Description of Air-Conditioner Components (1) Front Panel (2) Guide Louver (3) Remote Sensor (4) Wall Pipe (5) Wrapping Tape (6) Drainage hose (7) Connection pipe - 6 -...
  • Page 9: Remote Control Operation

    ◆Remote Control Operation Function-Remote control Note: • Don't drop the remote control. • Don't place the remote control in a location exposed to direct sunlight. • When the unit is restarted after stopped, it will automatically resume its last running mode, and the outdoor unit will start there after.
  • Page 10: Remote Control Operation

    ◆Remote Control Operation (Continued) Liquid Crystal Display. It shows all set contents. ON/OFF Button Press ON. Press OFF. T-ON Button. When pressing this button once, enter into T-ON setting, the icon of T-ON flash, every press of TIME+, the time of T-ON will be increased 1min.
  • Page 11: How To Insert Batteries

    ◆How to Insert Batteries 1. Remove the cover from the back of the remote control. 2. Insert the two batteries (Two AAA dry-cell batteries). 3. Re-attach the cover. NOTE: • Don’t mix different batteries. • Remove batteries when not in use for a longtime. •...
  • Page 12: Cleaning And Maintenance

    • Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might occur. • Liquids on the air conditioner may cause the risk of electric shock. Make sure not to spray wash your air conditioner in any case.
  • Page 13: Cleaning And Maintenance

    ④ Check the mounting frame of outdoor unit for damage. If damaged, please contact the Authorized Service Center. Check after Seasonal Use ① Cut off the power supply to air conditioner . ② Clean the filter and the indoor/outdoor unit. ③ Clear off the dust and foreign particles on outdoor unit.
  • Page 14: Trouble-Shooting

    3 minutes before the air conditioner will run. The air conditioner itself has no bad odor. If any, it is the bad odor accumulated from the environment. Solution: Clean the air filter (Refer to Page 10). If the problem persists please call the Authorized Service Center.
  • Page 15 ◆Trouble-Shooting Fault Air conditioner does not run. Air conditioner is poor in cooling (or heating) effect. Remote control cannot execute control. Water leaks from indoor unit. Water leaks from outdoor unit. Indoor unit has unusual noise. Cause Analysis • Power failure? •...
  • Page 16 ◆Trouble-Shooting Fault No air blows out from indoor unit. Moisture exists on outlet grill. In the event of any of the following, please contact Authorized Service Center. Cause Analysis • When the temperature of indoor heat exchanger is low during heating process, the indoor unit will stop blowing to prevent blowing of cold air (within 3 minutes).
  • Page 17: Installation Services

    2. Contact the local installation and service agency before installation. 3. For relocation of the air conditioner to another position, please contact the local Authorized Service Center. Basic Requirements for Installation Position Installation at the following places may cause failure of the air conditioning unit. Please contact installation and service agency if the installation at such places cannot be avoided.
  • Page 18: Grounding Requirement

    1. This air-conditioning unit is a Class I electrical appliance, reliable grounding measures must be taken for it. 2. The double color (yellow and green) cable inside the air conditioner is for grounding and shall not be used for other purposes nor can it be cut. Do not tighten with tapping screw; otherwise electric shock is possible.
  • Page 19: Installation Dimension Drawing

    ◆Installation Dimension Drawing - 17 -...
  • Page 20: Install Indoor Unit

    ◆Install Indoor Unit 1. Level with plumb line or spirit level. As the drain outlet is on left side, it is better that the left side shall be lower when adjusting the wall-mounted board. 2. Use screws to secure the wall-mounting frame on the wall.
  • Page 21: Install Indoor Unit

    ◆Install Indoor Unit Notes: If the connecting cable is not long enough, please contact your distributor for a piece of special cable with sufficient length. No joints are allowed in the middle of the cable. • Be sure to connect the cable correctly. Incorrect connection will cause fault to some electrical parts. •...
  • Page 22: Install Outdoor Unit

    ◆Install Outdoor Unit 1. Remove the handle at the right side plate of the outdoor unit (one screw). 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and make the connection. The fitting line distributing must be consistent with the indoor unit.
  • Page 23: Checks Items After Installation And Test Run

    ◆Install Outdoor Unit Check Items Is the installation reliable? Has the refrigerant gas leakage been checked? Is the thermal insulation of the unit sufficient? Is the drainage smooth? Does the power supply voltage accord with the rated voltage specified on the nameplate? Are the lines and pipelines correctly installed? Has the unit been safely grounded? Are the models of lines in conformity with...
  • Page 24: Electrical Schematic Diagram

    Electrical Schematic Diagram ◆Electrical Schematic Diagram (Indoor Unit) - 22 -...
  • Page 25: Electrical Schematic Diagram (Outdoor Unit)

    ◆Electrical Schematic Diagram (Outdoor Unit) - 23 -...
  • Page 26: Warranty

    Soleus International Inc. warrants the accompanying Soleus Air Wall Mounted Mini Split Heat Pump Air Conditioner (KFHHP-18-ID/KFHHP-18-OD) to be free of defects in material and workmanship for the applications specified in its operation instruction for the period of parts specified below.

This manual is also suitable for:

Kfhhp-18-odKfhhp-18

Table of Contents