Soleus Air KFTHP-9-ID Owner's Manual
Soleus Air KFTHP-9-ID Owner's Manual

Soleus Air KFTHP-9-ID Owner's Manual

13 seer mini-split

Advertisement

2
D
HWGG.1303-0017
莫丽珍
2013.03.04
C
HWGG.1202-0063
莫 丽 珍 2012.02.08
29

Advertisement

Table of Contents
loading

Summary of Contents for Soleus Air KFTHP-9-ID

  • Page 1 HWGG.1303-0017 莫丽珍 2013.03.04 HWGG.1202-0063 莫 丽 珍 2012.02.08...
  • Page 2 v.130219...
  • Page 3: Table Of Contents

    CAUTION All units must be installed by a licensed contractor or technician. Installation must be in accordance with this manual,NEC,State and Local Codes. Otherwise unit warranty will be void and serious damage to person and/or property may occur. Read all instruction manuals thoroughly before attempting installation. The Manufacturer shall NOT be liable for any damages or loss due to improper installation or operation or natural disasters.
  • Page 4: Safety Precautions

    Safety Precautions Symbols in this Use and Care Manual are interpreted as shown below. Be sure to follow this instruction. WARNING! DANGER! Remove the power source plug from a socket. CAREFUL! Pay Attention. Warning: Incorrect handling could cause a serious Grounding is essential.
  • Page 5: Identification Of Parts

    Identification of Parts Indoor Unit Air Intake Front Panel Emergency Panel Display Panel Air Outlet Vertical Adjustment Louver Horizontal Adjustment Louver Charcoal Filter (optional) Electrostatic Filter (optional) Air Filter Remote Control Air Intake Outdoor Unit Pipes and Power Connection Cord Drain Hose Note: Condensate water drains at COOLING or DRY operation.
  • Page 6: Remote Controller

    Identification of Parts Operating and Display Temperature display Display of environm- Run Indicator Timer Indicator ental temperature or It is on during It lights up during setting temperature operation. the set time. Power Indicator Sleep Indicator It lights up when It lights up during the power supply is on.
  • Page 7 Remote Control Remote Control The remote control transmits signals to the system. ON/OFF button Used to start and stop operation . Signal Transmitting Window TIMER button Setting Display Transmits signals to the system. Used to select TIMER operation. UP button (TOO COOL button) (60 f Used to increase the set room temperature and time(0.5~24h or 1~12h ).
  • Page 8 Remote Control Remote Control Some remote control s display: Feel Cool Dry Fan Heat SLEEP TIMER ON TMIER OFF AUTO FEEL Timer HIGH COOL Timer HEAT SWING Auto Low Mid High Sleep Swing Style.3 Style.1 Style.2. FEEL SPEED AUTOQUIET COOL POWERFUL SWING AUTO...
  • Page 9 Remote Control Remote Control How to Insert the Batteries Please slide and remove the cover. Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of Slide the cover battery are matched correctly. upwardly in the direction of the Re-attach the cover by sliding it back into position.
  • Page 10: Operation Instructions

    Operation Instructions FEEL mode operation procedure Operates by selecting automatically the operation mode(HEAT,DRY,FAN,COOL)depending on the room temperature during staring. With the remote control pointing toward the air conditioner. Turning on Press button, when the appliance receives the ON/OFF signal, the RUN indicator of the indoor unit lights up. SLEEP TIMER ON TMIER OFF FEEL...
  • Page 11 Operation Instructions TIMER mode It is convenient to set the timer on with TIMER button when you go out in the morning to achieve a comfortable room temperature when you get home. You can also set timer off at night to enjoy a good sleep. When the Remote When the Remote Control is ON,press...
  • Page 12: Maintenance

    Maintenance Air filter maintenance Front panel maintenance It is necessary to clean the air filter after using it for about 100 hours. Turn off the appliance first before disconnecting Clean it as follows: Cut off the from power supply. power supply Stop the appliance Grasp position "a"...
  • Page 13: Protection

    Protection Operating condition Noise pollution The protective device maybe trip and stop the appliance in the cases listed below. Install the air conditioner at a place that can bear its weight in order to operate Outdoor air temperature is over 75 f more quietly.
  • Page 14: Troubleshooting

    Troubleshooting The following cases may not always be a malfunction, please check it before asking for service. Analysis Trouble If the plug is not properly plugged. If batteries in the remote controller exhausted. Does not run If the protective device works to protect the appliance. If the protector trip or fuse is blown.
  • Page 15: Installation Instructions

    Installation Instructions Installation Diagram Distance from ceiling 6” should be over Distance from wall should be over 6”” Distance from the wall should be over 6” Distance from floor 6 feet should be over over Air intake distance from the wall Air intake distance from Should be over 12”...
  • Page 16 Installation Instructions Connecting of the Cabble Front panel Wiring between the indoor and outdoor units: Terminal (inside) 1) Remove the PCB cover from the indoor unit; 2) Refer to the wiring diagram attached to indoor unit COVER COVER when connecting cords to indoor unit terminals; 3) Reinstall the PCB cover.
  • Page 17 Installation Instructions Indoor Unit Installation 1. Installing the Mounting Plate Decide an installing location for the mounting plate according to the indoor unit location and piping direction. Keep the mounting plate horizontally with a horizontal ruler or dropping line. Drill holes of in depth on the wall for fixing the plate.
  • Page 18 Installation Instructions NOTE NOTE Piping Joints Thermal Insulation: Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape. wrapped with vinyl type The temperature of refrigerant circuit Thermal insulation will be high, please keep the interconnection able away from the copper tube.
  • Page 19 Installation Instructions 4. Connecting of the Cable Indoor Unit Front panel Connect the power connecting cord to the indoor unit Terminal (inside) by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit connection.
  • Page 20: Vacuum Pump

    Installation Instructions Outdoor Unit Installation 1.Install Drain Port and Drain Hose (for heat-pump model only) The condensate drains from the outdoor unit when the unit operates in heating mode. In order to protect the environment, install a drain port and a drain hose to direct the condensate water. Just install the drain port and rubber washer to the chassis of the outdoor unit, then Washer connect a drain hose to the port as the right figure shown.
  • Page 21 Installation Instructions Interconnection Cable Take off the cover for Interconnection cable of outdoor unit. Take off the block for Interconnection cable, then put the core of the power wire to the terminal and fix it according to the diagrams pasted to indoor and outdoor unit separately. Fix the accessory cable with the Interconnection cable block.
  • Page 28 0.36 0.36 0.36 0.36 22/28. 6...
  • Page 29 Soleus Home Comfort Soleus Home Comfort Soleus Home Comfort SOLEUS HOME COMFORT SOLEUS HOME COMFORT HOME COMFORT Soleus Home Comfort 17911 East Ajax Circle City of Industry,CA 91748 www.soleushomecomfort.com...