Maintenance
9-4
6
On the drum unit, slide the main charger cleaner
(green) back and forth 2 or 3 times to clean the
charger wire, then return it to its original position
(CLEANER HOME POSITION ).
IMPORTANT:
Remove the fixing tape on the main
charger cleaner before cleaning for the first time.
After cleaning, make sure you restore the main charger
cleaner to its home position.
7
When cleaning is complete, return the drum unit to
the original position.
8
Return the developer unit to its position, aligning
the guides at both ends with the slots in the
machine. Then, close the front cover.