OPERATION GUIDE
2
Lift the developer unit together with the toner
container out of the machine.
3
Remove the drum unit from the machine by holding
the green levers with both hands.
NOTE:
The drum unit is sensitive to light. Never
expose the drum unit to light for more than five
minutes.
4
Place the drum unit flat on a clean, level surface.
IMPORTANT:
Do not place the drum unit on end.
5
Use a clean, lint free cloth to clean dust and dirt
away from the metal registration roller.
IMPORTANT:
Take care not to touch the transfer roller
(black) during cleaning.
Maintenance
9