Energy Recovery Data - Atlas Copco GA 37+ Instruction Book

Oil-injected rotary screw compressors
Hide thumbs Also See for GA 37+:
Table of Contents

Advertisement

5.5

Energy recovery data

Reference conditions
See section
Reference conditions and limitations.
Effective working pressure
Consult section Compressor data for the normal working pressure.
Maximum allowed pressure of the heat exchanger
Oil side
15bar
Water side
10bar
Reading settings
In addition to other data, the following temperatures can be read on the Elektronikon display:
For air-cooled units:
The water inlet temperature of the energy recovery system
The water outlet temperature of the energy recovery system
For water-cooled units:
The water inlet temperature of the energy recovery system
The water outlet temperature of the energy recovery system
The cooling water outlet temperature of the compressor
Modifying settings
If the programmed warning settings for the water temperatures are exceeded, a warning indication is shown on
the Elektronikon:
Temperature input
Water inlet temperature of
energy recovery
Energy recovery water
outlet temperature
To modify a setting, consult section
Recoverable energy
The recoverable energy can be calculated from:
RECOVERED ENERGY (kW) = 4.2 x water flow (l/s) x water temperature rise (°C)
In the tables below, typical examples are given, except for the recovered energy.
92
Units
Minimum setting
°C
0
°C
0
Settings menu.
Nominal setting
Maximum setting
50
99
Depends on
99
application