11. Pour clean water along the inner edge of vessel 1 until water flows out of the outlet tube (1-View of
OSCi outlet), or until the water reaches the bottom of the sensor chamber (visible through the sight-
glass). The oleophilic filter will start to float. Do not push the filter down.
12. Put the cover back on the vessel and tighten the clamping ring.
13. Close/reposition the compressor bodywork.
14. Reset the service counter of the Elektronikon®. See section Elektronikon Warnings.
If the filters are not installed properly, oil-containing condensate can leave the OSCi.
When placing new activated carbon filters, the outgoing water may initially look black (car bon dust).
The carbon water is not harmful.
All filters, oil-containing tissues and water must be disposed of in an environmentally friendly and
safe manner and in line with the local recommendations and environmental legislation.
Each new filter is provided with a label. The correct position is marked on the label.
Used filters can be heavy.•See to it that no condensate comes into contact with eyes, mouth, ...
If the compressor has not been in operation during a long period, bacteria formation could occurin
side the OSCi. Depending on the amount of bacteria it is advised to clean the OSCi before putting the
compress or back into operation.