Insertion System - CanadianSolar CS6L-MS Installation Manual

Photovoltaic module
Table of Contents

Advertisement

The following methods are recommended only for single glass monofacial modules. Note that clamp overlap length of 40mm (or
1.50 in) when uplift load > 2400 Pa is allowed.
Modyle Type
CS6R-MS-HL/CS6R-
MB-HL
Modyle Type
CS6R-MS-HL/CS6R-MB-HL
*: test loads, please refer to section 6

6.3 INSERTION SYSTEM

 Insertion Method C shown below is recommended only for
monofacial modules.
 The mechanical load test with these mounting methods
were performed according to IEC 61215.
 Insertion methods can vary and depend on the mounting
structures. The installer needs to follow the mounting
guidelines recommended by the mounting system supplier.
Each module must be securely maintained through all its
length on two opposite sides. Install and tighten the
insertion profiles to the support structure using the
EN-Rev IM/GN-EN/1.2 Copyright © April, 2023. CSI Solar Co., Ltd.
Landscape installation, clamping on long side frame
Max Span
72 inches (1.83 m)
64 inches (1.63 m)
48 inches (1.22 m)
32 inches (0.81 m)
Portrait installation, clamping on short side frame
Max Span
48 inches (1.22 m)
32 inches (0.81 m)
24 inches (0.61 m)
Max Cantilever length
24 inches (0.61 m)
21.3 inches (0.54 m)
16 inches (0.41 m)
10.7 inches (0.27 m)
Max Cantilever length
16 inches (0.41 m)
10.7 inches (0.27 m)
8 inches (0.2 m)
hardware and instructions provided by the mounting
system manufacturer. The system designer and installer
are solely responsible for load calculations and for the
proper design of support structure.
 When installing insertion profiles, please take the following
measures into account:
1. Do not bend the module frame.
2. Do not touch the front glass or cast shadows onto it.
3. Do not damage the surface of the frame.
4. Ensure that the insertion profiles overlap the module
frame by at least 10 mm (0.39 in).
| 23
Downforce*
Uplift*
2650 Pa
2400 Pa
2800 Pa
2400 Pa
3600 Pa
3600 Pa
4000 Pa
3600 Pa
Downforce*
Uplift*
1800 Pa
1800 Pa
1800 Pa
1800 Pa
2000 Pa
2000 Pa
www.csisolar.com

Advertisement

Table of Contents
loading