This manual is only valid for the module types CS6A-P, CS6A-M, CS6V-P, CS6V-M, CS6P-P, and GENERAL SAFETY CS6P-M, CS6K-P, CS6K-M, CS6X-P, CS6X-M, CS6K-MS, CS6V-MS, CS6A-MS, CS6U-P and CS6U-M. · All installation work must comply with applicable Please retain this manual for future reference.
Installation Manual Annex ( Section Annex C: backsheet is torn. Module Specifications) on www.canadiansolar.com. Main electrical characteristics at STC are also stated · The PV module does not contain any serviceable parts. on each module label. Please refer to the datasheet Do not attempt to repair any part of the module.
This nameplate specifies the model type, as modules under any circumstances. Localized heavy well as the main electrical and safety characteristics loads may cause severe micro-cracks at cell level, of the module. which in turn may compromise module reliability. www.canadiansolar.com...
· Exposing modules to salt (i.e. marine environments) MODULE INSTALLATION or sulfur (i.e. sulfur sources, volcanoes) incurs the risk of module corrosion. PRECAUTIONARY MEASURES AND · Failure to comply with these instructions will void GENERAL SAFETY Canadian Solar Inc. warranty. ·...
If the measured open circuit voltage (Voc) and the racking system. short-circuit current (Isc) differ substantially from the specifications, this indicates that there is a wiring fault. · Do not place connectors in locations where water could easily accumulate. www.canadiansolar.com...
· Although the modules are certified to Safety Class Alternative Grounding Methods) on the website II, we recommend that they are grounded and that (www.canadiansolar.com). It is not possible to use module installation should comply with all local standard grounding methods for certain module electrical codes and regulations.
17~23 Nm (12.5~17.0 ft-lbs) respectively for M6 Mounting Methods) on our website (www. (1/4”-20) and M8 (5/16”-18) coarse thread bolts, canadiansolar.com). For information about depending on bolt class. In areas with heavy other installation hardware, please contact your wind loads, additional mounting points should local representative.
Page 10
Uplift load ≤ 2400 Pa Uplift load ≤ 2400 Pa Downforce load ≤ 5400 Pa Downforce load ≤ 2400 Pa Compatible module type: CS6A-P, CS6A-M, CS6A- Compatible module type: CS6A-P, CS6A-M, MS, CS6P-P and CS6P-M CS6P-P, CS6P-M and CS6A-MS Bolting on long frame side using four Bolting on long frame side using four innermost innermost mounting holes.
· Rev 3.4 was amended and released in Mar, 2016. · Rev 3.5 was amended and released in June, 2016. · Rev 3.6 was amended and released in Mar, 2017. CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario, Canada N1K 1E6 www.canadiansolar.com www.canadiansolar.com...