Alert - NSR Marine NGR-3000 User Manual

Hide thumbs Also See for NGR-3000:
Table of Contents

Advertisement

5.3 Alert

List of all alerts that could be generated:
ID
Ins Cat Prio
3056
1
B
C
3015
2
B
W
3055
3
B
W
3012
4
B
W
Ins: Instance of an alert;
Prio: Alert priority (W – Warning, C – Caution);
Cat: Alert category;
Escal: W – An unacknowledged warning will be repeated as warning after 4 minutes;
Resp: Transfer responsibility;
: "DGNSS Lost" takes effect when BEACON is selected.
*
When an alert occurs, the buzzer sounds (except for a caution) and the title of alert appears at
the bottom of display. Click on the bottom to enter the alert list.
Alert mark description:
MARK
MARK
Click [MENU]-[SETTINGS]-[ALERT] to open the [ALERT] screen, it shows all currently
Escal
Resp
/
/
HDOP exceeded
W
Yes
Loss of position
W
Yes
DGNSS Lost*
W
Yes
Integrity status
PRIORITY
WARNING
PRIORITY
WARNING
CAUTION
Alert Title
HDOP > 4.0 check antenna
Loss of position check antenna
Loss of differential signal
Accuracy is unsafe check antenna
STATE
ACTIVE-UNACKNOWLEDGED
ACTIVE-SILENCED
ACTIVE-ACKNOWLEDGED
STATE
ACTIVE-RESPONSIBILITY TRANSFERRED
RECTIFIED-UNACKNOWLEDGED
ACTIVE