Summary of Contents for NSR Marine NAVTEX NVX-1000
Page 1
USER MANUAL NAVTEX RECEIVER NVX-1000/NVX-3000 NVX-1000/NVX-3000 UM.E 20220916-08...
Page 2
NOTICE TO USERS Thanks for your purchasing this product NVX-1000/NVX-3000 NAVTEX RECEIVER. The copyright of this manual is owned by the manufacturer, NEW SUNRISE CO., LTD. (NSR). Prior written permission is required for copying or reproducing the manual or part of the manual. Please read this manual carefully to ensure proper use before installation and operation of the NVX-1000/NVX-3000.
Page 3
SAFETY INSTRUCTIONS FOR THE OPERATOR Warning Keep away from heater source or direct sunshine. Prohibition Don’t open the equipment. Only qualified personnel should work inside the equipment. Don’t disassemble or try to modify the equipment. Dangerous Turn off the power immediately when smoke or fire is emitted. SAFETY INSTRUCTIONS FOR THE INSTALLER Warning Connect the earth cord to ship’s body.
Page 4
MODIFY RECORD Modify by Date Paragraph Version Reason 2010/03/07 First edition NAVTEX station list 2014/09/30 update 2018/06/12 Standards 2019/05/06 Product update 2019/05/10 Meet IMO New Rule 2021/06/03 General modification Add BAM interface 2.3, 3.2, 4.1, 2021/08/05 4.3, 5, App.1 description etc. 2022/09/16 Generally modified NVX-1000/NVX-3000 UM.E 20220916-08...
CONTENTS 1. NAVTEX SYSTEM ....................1 1.1 NAVTEX ..................1 INTRODUCTION 1.2 NAVTEX ....................2 PRINCIPLE 1.3 NAVTEX ..................4 MESSAGE FORMAT 1.4 NAVTEX ..................5 STATION LIST 2. NVX-1000/NVX-3000 CONFIGURATION ..............8 2.1 NVX-1000/NVX-3000 O ................8 UTLINE 2.2 C NVX-1000/NVX-3000 ............
Page 6
4.3 M ..................17 ENU SETTING 4.3.1 S ....................18 TATION ETTING 4.3.2 M .................... 19 ESSAGE ETTING 4.3.3 A ..................20 DVANCED FUNCTION 4.3.4 S ....................22 YSTEM ETTING 4.3.5 D ....................24 IAGNOSTICS 4.3.6 S ......................30 ERVICE 5.
NVX-1000/NVX-3000 USER MANUAL 1. NAVTEX SYSTEM 1.1 NAVTEX introduction NAVTEX provides shipping with navigational and meteorological warnings and urgent information by automatic display and/or print out from a dedicated receiver. NAVTEX is a component of the IMO/IHO World-Wide Navigational Warning Service (WWNWS) defined by IMO Assembly resolution A.706(17), as amended, and the WMO Manual on Marine Meteorological Services, Part Ibis, Provision of warnings and weather and sea bulletins (GMDSS application).
NVX-1000/NVX-3000 USER MANUAL 1.2 NAVTEX principle For navigation purposes, the world is divided into 16 areas as shown in the figure below. Each NAVTEX station has an identification code, from the A to Z. The frequency assigned to NAVTEX are 518 kHz , 490 kHz and 4209.5 kHz, and many stations exist in the same service coverage. If the stations were to transmit without any rule, the system would collapse due to mutual interference.
Page 9
NVX-1000/NVX-3000 USER MANUAL [Figure 1-2] NAVAREA of the WWNWS NVX-1000/NVX-3000 UM.E 20220916-08...
NVX-1000/NVX-3000 USER MANUAL 1.3 NAVTEX message format For automatic identification of NAVTEX messages, each message has its ID No which is identified as B1, B2, B3 and B4 to indicate origin, category and serial number of the message. Character B1 is the identification letter of the NAVTEX station “A” to “Z”. Character B2 indicates the type of message “A”...
NVX-1000/NVX-3000 USER MANUAL 1.4 NAVTEX station list Country Freq. Area Station Station Latitude Longitude Broadcast Schedule (UTC) Area /Region (kHz) (nm) Belgium Oostende 51° 11'N 02° 48'E 0310, 0710, 1110, 1510, 1910, 2310 Estonia Tallinn 59° 30'N 24° 30'E 0320, 0720, 1120, 1520, 1920, 2320 0250, 0650, 1050, 1450, 1850, 2250 Iceland Reykjavik Radio...
Page 12
NVX-1000/NVX-3000 USER MANUAL Country Freq. Area Station Station Latitude Longitude Broadcast Schedule (UTC) Area /Region (kHz) (nm) Russian Novorossiysk 0300, 0700, 1100, 1500, 1900, 2300 44° 42'N 37° 44'E Federation Spain Cabo de la Nao 0350, 0750, 1150, 1550, 1950, 2350 38°...
Page 13
NVX-1000/NVX-3000 USER MANUAL Country Freq. Area Station Station Latitude Longitude Broadcast Schedule (UTC) Area /Region (kHz) (nm) 0000, 0400, 0800, 1200, 1600, 2000 Jayapura 02° 31'S 140° 43'E 0010, 0410, 0810, 1210, 1610, 2010 Ambon 03° 42'S 128° 12'E Indonesia Makassar 05°...
NVX-1000/NVX-3000 USER MANUAL 2.3 Supply scope of NVX-1000/NVX-3000 Table 2-1 Supply scope of NVX-1000/NVX-3000 Standard Supply Scope Name Type Part No. Q’ty Remarks NVX-1000/ N991110/ Main Unit 1 pc NVX-3000 N991130 Loop Antenna (with meters RG58 cable, TNC NXA200 1 pc connector) Installation Materials Steel Tie...
NVX-1000/NVX-3000 USER MANUAL 3. NVX-1000/NVX-3000 SPECIFICATIONS 3.1 Software characteristics 3.1.1 B1 and B2 characters The B1 characters identifying the different transmitter coverage areas and the B2 characters identifying the different types of messages are defined by IMO and chosen from table I of ITU-R Recommendation M.625, combination numbers 1-26.
NVX-1000/NVX-3000 USER MANUAL 4. HOW TO OPERATE 4.1 Outline 4.1.1 Outline of main unit - Front View - - Rear View - [Figure 4-1] The outline of NVX-1000/NVX-3000 main unit NVX-1000/NVX-3000 can be operated by touch-screen or key & knob on panel. 4.1.2 Power On / Off By pressing the PWR key to switch on the NVX-1000/NVX-3000 receiver.
NVX-1000/NVX-3000 USER MANUAL 4.1.3 The default screen and control keys The default display is the Message List screen - [MSG List], as below. ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑪ ⑭ ⑮ ⑫ ⑯ ⑨ ⑰ ⑬ ⑱ ⑩...
NVX-1000/NVX-3000 USER MANUAL Page up Page down MENU To [MAIN MENU] VIEW To [VIEW MESSAGE] To tag the selected message PRING To print the selected message TO INS To INS the selected message The available keys are as follows. Panel Button Description Turn to select an item.
Page 21
NVX-1000/NVX-3000 USER MANUAL STATION SETTING MESSAGE SETTING PRINT ADVANCED TASK FUNCTION CH2 FREQUENCY SYSTEM BUZZER PORT SET SYSTEM SETTING DATE/TIME SET LANGUAGE MAIN MENU PRINTER SET DISPLAY SET PROGRAM VERSION HARDWARE TEST DIAGNOSTICS RECEIVER TEST ALARM LIST Menu Structure COM MONITOR ADVANCED RF SIGNAL TEST SERVICE...
NVX-1000/NVX-3000 USER MANUAL 4.2 Message operation 4.2.1 Message list NVX-1000/NVX-3000 receives the maritime safety information on 518kHz, international NAVTEX frequency 490kHz and 4209.5kHz, national NAVTEX frequencies. When a message is received and stored, a message line will be added into the message list. If the antenna indication is flickering upper the screen, the signal is being received on the frequency...
NVX-1000/NVX-3000 USER MANUAL 4.2.3 Message tag points to the message, In [MSG List], when the arrow click TAG, you can Lock and save a message permanently. click TAG again to release the lock of message. In NVX-1000/NVX-3000, after 72 hours since a message was received (including the shutdown time), the message will be automatically deleted.
NVX-1000/NVX-3000 USER MANUAL [Figure4-8] Main menu screen 4.3.1 Station Setting It’s to select certain stations to reject the messages broadcasted. Click [STATION SETTING] to enter the following screen. [Figure4-9] Station setting screen (1) On each frequency, a station ID can be set for receiving rejection, automatic printing and output to INS.
NVX-1000/NVX-3000 USER MANUAL The default setting is like that all stations are not rejected to receive while all automatic printing and output to INS are disabled. 4.3.2 Message Setting Messages received from the stations not rejected as preset in [STATION SETTING] will be saved or not saved in the memory depending on [MESSAGE SETTING].
NVX-1000/NVX-3000 USER MANUAL The default setting is like that all message types are not rejected to store while all automatic printing and output to INS are disabled. 4.3.3 Advanced function Click [ADVANCED FUNCTION] at [MAIN MENU] to enter the following screen. In [ADVANCED FUNCTION], it offers three sub function items:PRINT, TASK, LOG.
Page 27
NVX-1000/NVX-3000 USER MANUAL [Figure4-15] Advanced print screen (2) Click PRINT, [CONFIRM] window will appear, select it. [Figure4-16] Advanced print screen (3) Click TASK to enter the [TASK] screen, it is to display all the PRINT and TO INS task list. [Figure4-17] Task screen NVX-1000/NVX-3000 UM.E 20220916-08...
NVX-1000/NVX-3000 USER MANUAL Click LOG to enter the [LOG] screen, it is to display NAVTEX LOG. [Figure4-18] LOG screen 4.3.4 System Setting NVX-1000/NVX-3000 contains six system setting items as follows: [Figure4-19] System setting screen [Figure4-20] Port set screen NVX-1000/NVX-3000 UM.E 20220916-08...
Page 29
NVX-1000/NVX-3000 USER MANUAL A/B/L MESSAGE ON/OFF ALARM NEW MESSAGE ON/OFF SYSTEM BUZZER SYSTEM ALARM ON/OFF KEY BUZZER ON/OFF 4800/9600/19200/ BAM/INS PORT 38400/115200 PORT SET 4800/9600/19200/ GPS PORT 38400/115200 MODE UTC/LMT DATE-UTC INPUT DATE/TIME SET TIME-UTC INPUT SYSTEM SETTING ZONE INPUT LANGUAGE ENG/中文...
NVX-1000/NVX-3000 USER MANUAL A list of user settings that are non-volatile. 1. Station Setting: B1 for Store, Print and INS in 518KHz, 490KHz and 4209.5KHz 2. Message Setting: B2 for Store, Print and INS in 518KHz, 490KHz and 4209.5KHz 3. MENU LANGUAGE 4.
Page 31
NVX-1000/NVX-3000 USER MANUAL 4.3.5.1 PROGRAM VERSION Click [PROGRAM VERSION] to enter the following view. [Figure4-23] Program version screen 4.3.5.2 HARDWARE TEST Click [HARDWARE TEST] to enter the following view. [Figure4-24] Hardware test screen ➢ LCD TEST LCD TEST is designed to test whether the LCD is working or not. Click [LCD TEST] to enter the test screen, turn knob continuously to test the LCD.
Page 32
NVX-1000/NVX-3000 USER MANUAL ➢ KEY TEST KEY TEST is designed to test whether the key, knob and touch-screen are working or not. Click [KEY TEST] to enter the following view. KEY test: press the DIM key. turn the knob to left and right, then press it. KNOB test:...
Page 33
NVX-1000/NVX-3000 USER MANUAL [Figure4-28] Printing test screen ➢ MEMORY TEST [MEMORY TEST] is designed to test whether the memory is working or not. Click [MEMORY TEST] to enter the following view. When the STATE column appears OK, it means the memory is good. [Figure4-29] Memory test screen 4.3.5.3 RECEIVER TEST Click [RECEIVER TEST] to enter the following screen.
Page 34
NVX-1000/NVX-3000 USER MANUAL [Figure4-30] Receiver test result screen 4.3.5.4 ALERT LIST Click [ALERT LIST] to enter the following view. [ALERT LIST] is to check alerts. In the [ALERT LIST], there are four sub items: to view the alert, mute the alert, acknowledge and check the log.
Page 35
NVX-1000/NVX-3000 USER MANUAL [Figure4-32] Alert view screen [Figure4-33] Alert log screen Alert description: Instance Category Priority ALF Title ALF Description 3122 WARNING SAR RX Incoming SAR info. Check NVXTEX 3115 WARNING IMPAIRED RADIO NAVTEX: Receiver malfunction 3062 WARNING NAVTEX FAULT NAVTEX: Built in self test failure 3062 WARNING GENERAL FAULT...
NVX-1000/NVX-3000 USER MANUAL 4.3.5.5 COM MONITOR Click [COM MONITOR] to enter the following view. It’s to check the sentence from BAM/INS and NMEA. [Figure4-34] COM monitor screen 4.3.6 Service Click [SERVICE] item at [MAIN MENU]. Input the password to enter the [SERVICE] screen. [Figure4-35] Service-Password enter [Figure4-36] Service screen NVX-1000/NVX-3000 UM.E 20220916-08...
Page 37
NVX-1000/NVX-3000 USER MANUAL ADVANCED MENU LOCK-ENG B-SIGNAL Y-SIGNAL RF SIGNAL TEST DOT PATTERN PHASING SERVICE SEQUENCE SYSTEM SETTING MESSAGE 518K FACTROY SET MESSAGE 490K REBOOT MESSAGE 4209K MESSAGE ALL [Figure4-37] Service menu structure NVX-1000/NVX-3000 UM.E 20220916-08...
NVX-1000/NVX-3000 USER MANUAL 5. INSTALLATION 5.1 Antenna The NXA200 loop antenna connected to NVX-1000/NVX-3000, should be kept away from other transmitting elements to avoid damage although NVX-1000/NVX-3000 might withstand 30 volts of RF high voltages. Generally the NAVTEX antenna should be 6 meters away from the MF/HF antenna, and 1 meter from VHF antenna.
NVX-1000/NVX-3000 USER MANUAL 5.3 BAM/INS connection NVX-1000/NVX-3000 can be connected to BAM system/INS. BAM system/INS RS422 NVX-1000/NVX-3000 RS422 OUT (+) Pin 6 INS IN (+) OUT (-) Pin 7 INS IN (-) IN (+) Pin 8 INS OUT (+) IN (-) Pin 9 INS OUT (-) 5.4 External alarm...
NVX-1000/NVX-3000 USER MANUAL - Serial port setting SERIAL. The output of NPT-100 should be set as - Baud rate setting The default rate for NVX-1000/NVX-3000 is 4800bps. If other rate except 4800bps is set for the printer, NVX-1000/NVX-3000 has to be set for the same rate in [SERVICE] menu. 5.7 Digital interface Digital interface sentence -- IEC 61162-1 Input sentences of NMEA IN port...
NVX-1000/NVX-3000 USER MANUAL APPENDIX 1 ALERT SOLUTION ALERT SOLUTION NAV RX NAVTEX MESSAGE notification, non-product failure. METEOR RX NAVTEX MESSAGE notification, non-product failure. SAR RX NAVTEX MESSAGE notification, non-product failure. Restart it 1-3 times, If it fails to return to normal contact IMPAIRED RADIO the manufacturer.
Page 44
NVX-1000/NVX-3000 USER MANUAL ARC - Alert command refused $--ARC, hhmmss.ss, aaa, x.x, x.x, c*hh <CR><LF> +------------------------------ 5 +---------------------------- 4 +-------------------------- 3 +----------------------- 2 +---------------------1 1. Time 2. Manufacturer mnemonic code 3. Alert identifier 4. Alert instance, 1 to 999999 5. Refused alert command, A, Q,O or S HBT –...
Page 45
NVX-1000/NVX-3000 USER MANUAL On receiving this query, the NAVTEX receiver will respond with one NRM sentence for each mask type and frequency combination that it supports. NRX – NAVTEX received message $--NRX,xxx,xxx,xx,aaxx,x,hhmmss.ss,xx,xx,xxxx,x.x,x.x,A,c---c*hh <CR><LF> +------------------------ 13 | +------------------------ 12 +------------------------- 11 +------------------------- 10 +-------------------------- 9 | +---------------------------- 8...
Page 46
NVX-1000/NVX-3000 USER MANUAL 1. UTC of position fix 2. Status: A=data valid, V=navigation receiver warning 3. Latitude, N/S 4. Longitude, E/W 5. Speed over ground, knots 6. Course over ground, degrees true 7. Date: dd/mm/yy 8. Magnetic variation, degrees E/W 9.
Need help?
Do you have a question about the NAVTEX NVX-1000 and is the answer not in the manual?
Questions and answers