Omron D4GL-1AFA-A4 Quick Start Manual page 8

Guard lock safety-door switch
Table of Contents

Advertisement

Contact Form
Indicates conditions where the Key is inserted and the lock is applied. Terminals 12 and 41 are connected internally (as per BIA GS-ET-19).
Model
Contact
D4GL-@AF@-@
1NC/1NO + 1NC/
1NO
D4GL-@BF@-@
1NC/1NO + 2NC
D4GL-@CF@-@
2NC + 1NC/1NO
D4GL-@DF@-@
2NC + 2NC
D4GL-@EF@-@
2NC/1NO + 1NC/
1NO
D4GL-@FF@-@
2NC/1NO + 2NC
D4GL-@GF@-@
3NC + 1NC/1NO
D4GL-@HF@-@
3NC + 2NC
8
Contact form
(door open/closed
detection switch and lock
monitor switch contacts)
11
12
41
42
33
34
53
54
11
12
41
42
33
34
51
52
11
12
41
42
21
22
53
54
11
12
41
42
21
22
51
52
11
12
41
42
21
22
53
54
33
34
11
12
41
42
21
22
51
52
33
34
11
12
41
42
21
22
53
54
31
32
11
12
41
42
21
22
51
52
31
32
Operating pattern
Lock position
11-42
33-34
53-54
Stroke
Operation Key insertion
Extraction completion
completion position
position
Lock position
11-42
33-34
51-52
Stroke
Operation Key insertion
Extraction completion
completion position
position
Lock position
11-42
21-22
53-54
Stroke
Operation Key insertion
Extraction completion
completion position
position
Lock position
11-42
11-42
21-22
21-22
51-52
51-52
Stroke
Operation Key insertion
Extraction completion
completion position
position
Lock position
11-42
11-42
21-22
21-22
33-34
33-34
53-54
53-54
Stroke
Operation Key insertion
Extraction completion
completion position
position
Lock position
11-42
21-22
33-34
51-52
Stroke
Operation Key insertion
Extraction completion
completion position
position
Lock position
11-42
21-22
31-32
53-54
Stroke
Operation Key insertion
Extraction completion
completion position
position
Lock position
11-42
21-22
31-32
51-52
Stroke
Operation Key insertion
Extraction completion
completion position
position
Safety Sensors / Components
Remarks
Only NC contact 11-12
has an approved direct
opening mechanism.
ON
The terminals 11-42, 33-
34, and 53-54 can be
used as unlike poles.
Only NC contact 11-12,
has an approved direct
opening mechanism.
ON
The terminals 11-42, 33-
34, and 51-52 can be
used as unlike poles.
Only NC contacts 11-12
and 21-22 have an ap-
proved direct opening
mechanism.
ON
The terminals 11-42, 21-
22, and 53-54 can be
used as unlike poles.
Only NC contacts 11-12
and 21-22 have an ap-
proved direct opening
mechanism.
ON
The terminals 11-42, 21-
22, and 51-52 can be
used as unlike poles.
Only NC contacts 11-12
and 21-22 have an ap-
proved direct opening
ON
mechanism.
The terminals 11-42, 21-
22, 33-34, and 53-54 can
be used as unlike poles.
Only NC contacts 11-12
and 21-22 have an ap-
proved direct opening
ON
mechanism.
The terminals 11-42, 21-
22, 33-34, and 51-52 can
be used as unlike poles.
Only NC contacts 11-
12, 21-22, and 31-32
have an approved direct
ON
opening mechanism.
The terminals 11-42, 21-
22, 31-32, and 53-54 can
be used as unlike poles.
Only NC contacts 11-12,
21-22, and 31-32 have
an approved direct
ON
opening mechanism.
The terminals 11-42, 21-
22, 31-32, and 51-52 can
be used as unlike poles.

Advertisement

Table of Contents
loading

Table of Contents