Omron D4GL-1AFA-A4 Quick Start Manual page 6

Guard lock safety-door switch
Table of Contents

Advertisement

Connections
Indicator
Internal Circuit Diagram
D
Green (+)
D
Orange (+)
LED
LED
(Green)
(Orange)
5 to 24V DC
CRD CRD
ZD
ZD
COM (−)
Circuit Connection Example
• Terminals 12 and 41 are connected internally and so connect termi-
nals 11 and 42 for safety-circuit input. (BIA GS-ET-19)
• Connect terminals 21 and 22 and terminals 51 and 52 in series
when using as safety-circuit input (redundancy circuit for terminals
11 and 12 and terminals 41 and 42 above). Connect the terminals
individually when using as auxiliary-circuit input (e.g., terminals 21
and 22 for safety-door open/closed monitoring and terminals 51
and 52 for monitoring the lock status).
• In the following connection example, terminals 21 and 22 and ter-
minals 51 and 52 are used as auxiliary-circuit input.
Connection Example for D4GL-1HFA-A
51
12
41
11
21
31
O2
O1 (Green)
(Green)
Indicator
(Green)
E1
O4 (Orange)
Indicator
O3 (Orange)
(Orange)
• Direct opening contacts used as safety-circuit input are indicated
with the
mark. Terminals 11 and 12 and terminals 21 and 22
are direct opening contacts.
• Connect the indicators in parallel to the auxiliary circuits or termi-
nals E1 and E2.
• Although the 3 lines are connected at the time of delivery, rewire
them as necessary for the application.
• The following table shows the connection configuration required to
make the green indicator light when the door is closed and the
orange indicator light when the solenoid turns ON.
Indicator
Terminal
number
Green indicator
O1
Orange indicator
O2
Common
O3
• If an indicator is connected in parallel to a direct opening contact,
when the indicator breaks, a short-circuit current will be generated,
possibly resulting in an installation malfunction.
• Do not switch standard loads for more than 2 circuits at the same
time. Otherwise, the level of insulation may decrease.
• The solenoid has polarity. Be sure to connect terminals with the
correct polarity.
6
42
Safety
circuit
52
Auxiliary
circuit
22
Auxiliary
circuit
32
Auxiliary
circuit
E2
Lead wire
Connected
color
terminal
number
Green
32
Orange
E1
Black
E2
Safety Sensors / Components