Olivetti d-Copia 3001MF Service Manual page 148

Hide thumbs Also See for d-Copia 3001MF:
Table of Contents

Advertisement

Section
Description
Paper
30
conveying
Misfeed in registration/
section
transfer section
Fuser
40
section
Misfeed in fuser section
(MP tray)
41
Misfeed in fuser section
(cassette 1)
42
Misfeed in fuser section
(cassette 2)
43
Misfeed in fuser section
(optional cassette 3)
44
Misfeed in fuser section
(optional cassette 4)
47
Misfeed in fuser section
(duplex section)
Eject
50
section
Misfeed in eject section
51
Misfeed in job separa-
tor eject section
Y112040-6
Conditions
The registration switch (RSW) does not turn off within
specified time of the feed switch 1 (FSW1) turning off.
The registration switch (RSW) does not turn off within
specified time of the feed switch 1 (FSW1) turning on.
The registration switch (RSW) does not turn on within
specified time of the feed switch 1 (FSW1) turning on.
The registration switch (RSW) does not turn off within
specified time of the MP feed switch (MPFSW) turning
off.
The eject switch (ESW) does not turn on within specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within
specified time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn on within specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within
specified time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn on within specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within
specified time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn on within specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within
specified time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn on within specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within
specified time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn on within specified
time of the registration clutch (RCL) turning on.
The feedshift switch (FSSW) does not turn on within
specified time of the registration clutch (RCL) turning on.
The eject switch (ESW) does not turn off within specified
time of the registration switch (RSW) turning off.
The eject switch (ESW) does not turn off within specified
time of the registration clutch (RCL) turning on.
The job separator eject switch (JESW) does not turn on
within specified time of the feedshift switch (FSSW) turn-
ing on.
The job separator eject switch (JESW) does not turn off
within specified time of the feedshift switch (FSSW) turn-
ing off.
The job separator eject switch (JESW) does not turn off
within specified time of the feedshift switch (FSSW) turn-
ing on.
Service Manual
2K5
Specified time
1314 ms
1100 ms
1100 ms
1686 ms
2321 ms
1336 ms
2321 ms
1336 ms
2321 ms
1336 ms
2321 ms
1336 ms
2321 ms
1336 ms
2321 ms
1336 ms
2321 ms
2321 ms
1350 ms
714 ms + Paper
length
1350 ms