Functional characteristics
TIG welding
5.1.5
Operating modes (functional sequences)
5.1.5.1
Explanation of symbols
Symbol
Meaning
Press torch trigger 1
Release torch trigger 1
I
Current
t
Time
Gas pre-flow
Ignition current
Up-slope time
Spot time
Main current (minimum to maximum current)
AMP
Secondary current
AMP%
Pulse current
Down-slope time
End-crater current
Gas post-flow
18