Regency Classic C34 Series Owners & Installation Manual page 17

Direct vent freestanding gas stove
Table of Contents

Advertisement

Description
Attic Insulation Shield 12"
Attic Insulation Shield
- Cold Climates 36"
Basic Horizontal Termination Kit (A)
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap
High Wind Horizontal Cap
Horizontal Square Termination Cap
Vertical Termination Cap
Storm Collar
Adjustable Flashing 0/12-6/12
Adjustable Flashing 6/12-12/12
Vinyl Siding Standoff
Vinyl Siding Shield Plate
Snorkel Termination 14"
Snorkel Termination 36"
Restrictor Disk
Extended Vertical Termination Cap
Chimney Conversion Kit A (USA only)
Chimney Conversion Kit B (USA only)
Chimney Conversion Kit C (USA
only)
Wall Firestop
Colinear Flex Connectors
* Olympia Ventis DV applicable for the following units only: B36XTE, B36XTCE, B41XTE, B41XTCE, CV40E, CB40E, CC40E, CV72E, P36, P36E
FPI
946-506/P
Vent Guard (Optional) for AstroCap
**510-994
Rigid Pipe Adaptor (Must use with all rigid piping)
640-530/P
Riser Vent Terminal
** The rigid pipe adaptor is not required on the C34, U39, H15, H27 & H35.
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
4" x 6-5/8" Venting
(L)
Run (X)
0" (0mm)
4-7/8" (124mm)
6" (152mm)
8" (203mm)
9" (229mm)
10-1/8" (257mm)
12" (305mm)
12-1/4" (311mm)
24" (610mm)
20-5/8" (524mm)
36" (914mm)
29" (737mm)
48" (1219mm)
37-7/16" (951mm)
Note: Horizontal runs of vent must be level, or have a 1/4" rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.
Selkirk
American Metal
Simpson
Direct Temp™
Products®
Direct Vent Pro
®
Amerivent Direct
46DVA-IS
N/A
4DAIS12
N/A@ FPI
N/A
N/A
4DAIS12
Disc.
4DT-HKA
4DHTK2
46DVA-KHA
4DT-HKB
4DHTK1
(Changed Components)
Disc.
4DT-VKC
4DHTK
46DVA-VCH
N/A
N/A
46DVA-HC
N/A
N/A
46DVA-HC
4DT-HHC
4DHC
46DVA-VC
4DT-HVC
4DVC
46DVA-08A
4DT-SC
4DSC
46DVA-F6
4DT-ST14
4D12S
46DVA-F12
4DT-ST36
4D36S
46DVA-VSS
4DT-VS
N/A
N/A
4DT-VSP
N/A
46DVA-SNK14
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
46DVA-KCA
N/A
N/A
46DVA-KCB
N/A
N/A
46DVA-KCC
N/A
N/A
46DVA-WFS
N/A
N/A
46DVA-ADF
N/A
N/A
946-205
946-208/P
946-523/P
946-206
Rise (Y)
13-7/8" (340mm)
16-1/2" (419mm)
18-5/8" (473mm)
20-3/4" (527mm)
29-1/8" (740mm)
37-1/2" (953mm)
45-15/16" (1167mm)
Security
Metal-Fab™
Secure- Vent®
Sure Seal
N/A
SV4RSA
N/A
N/A
4DHTKA
SV-SHK
4DHTKB
SV-HK
4DHTK
SV-FK
N/A
N/A
N/A
N/A
4DHT
SV4CHC-1
4DVT
SV4CGV-1
4DSC
SV4FC
4DST14
SV4STC14
4DST36
SV4STC36
4DVS
SV4VS
N/A
SV4VS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Vinyl Siding Shield for Riser Vent Terminal
Vent Guard (Optional) for Riser Vent Terminal
AstroCap Horizontal Cap
Vinyl Siding Standoff for AstroCap
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
American Metal Products: www.americanmetalproducts.com
Metal-Fab Sure Seal: www.mtlfab.com
Security Secure Vent: www.securitychimneys.com
Industrial Chimney Company: www.icc-rsf.com
Olympia Ventic DV: www.olympiachimney.com
Regency
CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove
®
installation
ICC Excel
Olympia
Ventis DV*
Direct
N/A
VDV-AIS04
TM-4AS
N/A
TM4-HTK
VDV-KW04
TM4-HTK
VDV-K04
N/A
N/A
TM-4VT
VDV-VCHW04
TM-4DHT
N/A
TM-4HT
VDV-HC04
N/A
N/A
TM-SC
VDV-SC04
TF-4FA
VDV-F0406
TF-4FB
VDV-SSO
TM-VSS
N/A
N/A
N/A
TM-4ST14
N/A
TM-4ST36
N/A
TM-4DS
N/A
N/A
N/A
TM-4CA6
N/A
TM-4CA7
N/A
TM-4CA8
N/A
TM-4TR
VDV-FS04
N/A
N/A
|
17
|
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic c34-ng10Classic c34-lp10Classic c34

Table of Contents