Regency C34-LP2 Owners & Installation Manual

C34 series classic direct vent freestanding gas stove
Table of Contents

Advertisement

C34 Classic Direct Vent
Freestanding Gas Stove
WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Tested by:
908-584a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
www.regency-fire.com
MODELS:
C34-NG2 Natural Gas
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Installation Manual
Classic C34 model shown above features optional
gold plated door and gold legs.
C34-LP2 Propane
FOR YOUR SAFETY
What to do if you smell gas:
® Do not try to light any appliance
® Do not touch any electrical switch:
do not use any phone in your
building.
® Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
® If you
cannot reach your gas
supplier, call the fire department.
Owners &
01/09/06

Advertisement

Table of Contents
loading

Summary of Contents for Regency C34-LP2

  • Page 1 Classic C34 model shown above features optional gold plated door and gold legs. MODELS: C34-NG2 Natural Gas C34-LP2 Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fire or explosion may result causing property damage, ®...
  • Page 2 CLASSIC Direct Vent Freestanding Gas Stove. INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Room Heater to the following standards: CAN/CGA-2.17- M91, ANSI Z21.88b-2003/CSA 2.33b-2003.
  • Page 3: Table Of Contents

    Replacement/Spare Parts list ........32 - Instructions for Converting a Factory Built Metal Chimney ..........22 Warranty - Instructions for Converting a Masonry Chimney .. 23 System Data Table ..........24 Warranty ..............35 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 4: Safety Label

    Massachusetts. For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length. For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 5: Installation

    5) This appliance must be connected to the solid, continuous surface (e.g. wood, met- specified vent and termination cap to the outside of the building envelope. al, concrete). This may be the floor, or it can Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 6: Installation Checklist

    1) Clocking the appliance to ensure the correct Extra provision for combustion air is not firing rate (rate noted on label) after burning required. appliance for 15 minutes. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 7: Optional Fan Installation

    See diagram 2. Diagram 1 Diagram 4 Caution: Ensure that the wires do not touch any hot surfaces. Note: The #8 ground lug is a dedicated ground for mobile home use only. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 8: Pedestal Assembly

    See diagram above. 4) Loosen the screws of the nutserts. Anchoring Brackets Hold 4) Push the Regency logo into the two holes Down Package Part# 846-585 5) Remove the fan assembly from the key slots in the front bottom left corner of the pedes- at the fan base and pull fan out through the tal cover plate.
  • Page 9: Venting

    1) Wear gloves and safety glasses for pro- tection. 2) Exercise extreme caution when using lad- ders or on roof tops. 3) Be aware of electrical wiring locations in walls and ceilings. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 10: Exterior Vent Terminal Locations

    INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 11: Rigid Pipe Venting Components List

    Vent Guard (Optional) 946-208/P Vent Guard (Optional) - Riser Vent Terminal 640-530/P Riser Vent Terminal 946-523/P AstroCap Horizontal Cap 946-205 Vinyl Siding Shield for Riser Vent Terminal 946-206 Vinyl Siding Standoff - AstroCap Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 12: Rigid Pipe Venting Systems

    GS, American Metal Products, Ameri Vent Direct vent and Selkirk Direct-Temp. FPI , and FPI AstroCap are the proprietary trademarks of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 13: Venting Arrangements

    Example B) Offset to Vertical Vent. A 15 ft. vertical run with 4 ft. horizontal offset distance falls within the shaded area and is an allowable installation with Vent Restrictor Position "R" (Right). Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 14: Horizontal And Vertical Venting With Two Elbows

    7' Max. 5' Min. between 90 elbows is re- 5' Min. 8' Max. 6' Min. quired. Lengths do not include elbow indicated. Vent restrictor position C (fully open), refer to page 9. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 15: Dv Stove Horizontal Vent Kit 945-216

    Note: if the centerline cannot be area after snow falls, and clear to pre- met, the adjustable sections will vent accidental blockage of venting sys- have to be cut. tem. When using snow blowers, make Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 16 Mill-Pac. All outer joints may point, stainless steel). Note: pilot holes will the 4" dia. flex liner. be sealed with high temperature need to be drilled through the wall thimble silicone. on all 4 corners. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 17: Dura-Vent Termination Systems

    Wall Strap Wall Thimble Parts not supplied by DuraVent 946-506/P Vent Guard (Optional) 640-530/P Riser Vent Terminal (Optional) 946-205 Vinyl Siding Shield for Riser Vent Terminal 946-208 Vent Guard for Riser Vent Terminal Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 18 FPI venting systems as well as Simpson Dura-Vent® and Direct Vent GS. Regency , and Regency AstroCap are the proprietary trademarks of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 19: Dura-Vent Horizontal Installations

    Horizontal Termination. NEVER install Hint: Apply silicone to female end. the snorkel upside down. b) Horizontal runs of vent must be sup- ported every three feet. Wall straps are available for this purpose. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 20: Dura-Vent Vertical Termination

    Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, Note: If an offset is necessary in the attic and mark the spot where the vent will to avoid obstructions, it is impor- Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 21: Offset Chart

    2) Place the support in the opening. Lower it section. floor, including closets and storage to the correct height as determined by the spaces, through which the vertical vent table and diagram below. passes, must be enclosed. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 22: Converting A Class-A Metal Chimney Or Masonry Chimney To A Direct Vent System

    Diagram 5 Diagram 1 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 23: Instructions For Converting A Masonry Chimney

    Re-drill larger holes on con- of the masonry chimney using a bead of section. nector as needed. Be careful to insure that non-hardening sealant-adhesive. IF the the connector is centered in the opening Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 24: System Data Table

    If test pressures equal to or less than 1/2 psig are used then this appliance must be isolated from the piping system by closing its individual manual shut-off valve during the testing. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 25: Log Set Installation

    29. Watch the flame to see if it flows pins in the back of the unit. The flat side of smoothly around from one end to the other. the log facing the back of the unit. Carefully Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 26: Door Handle

    UL approved may be used. 2) Connect the two wires to the gas valve. See diagram below. Connect the wires as per the wiring diagram. Use the Thermostat Wire Table to determine the maximum wire length. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 27: Wiring Diagram

    Do not cut or remove the grounding prong from this plug. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 28: Operating Instructions

    1) Turn burner OFF using "ON/OFF" switch. PLACE. 2) Turn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 29: Aeration Adjustment

    Note: Aeration Adjustment should only set but may need adjusting due to either the be performed by an authorized local gas supply or altitude. Regency Installer at the time of installation or service. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 30: Normal Operating Sounds Of Gas Appliances

    6) Keep the area near the appliance clear and create carbon buildup and will al- free from combustible materials, gasoline ter the unit’s performance which and other flammable vapours and liquids. is not covered under warranty. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 31: Gold Plated Doors

    2. Note: Access panel only has to be loos- ened to be taken out. 4) Remove front cover with piezo igniter by removing two (2) sheet metal screws. 5) Disconnect piezo wire. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 32: Parts List

    Top Relief Plate Gasket 290-021 Air Baffle Plate Capscrew 1/4 x 1-3/4" NC Upper Air Passage Assembly 490-081 Flue Restrictor 490-520 Top Assembly 490-042 Rear Panel 908-584 Manual *Not available as a replacement part. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 33 Deflector-Top Rear Log - LP 490-932 Complete Log Set 902-180 Front Log 902-186 Rear Log 902-182 Top Log 902-151 Ember 902-153 Rockwool 904-537 Gas Inlet Pipe (12") *Not available as a replacement part. Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 34: Base Options

    Cast Legs - Gold (4/set) 125) 490-002 Rear Cover Plate 850-126 Cast Legs - Black (4/set) 850-128 Cast Legs - Brush Nickel (4/set) *Not available as a replacement part. 142) 850-125 Steel Legs (4/set) Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater...
  • Page 35: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-field service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 36 Dealer Name & Address: ________________________________________________ ______________________________________________________________________ Installer: ______________________________________________________________ Phone #: ______________________________________________________________ Date Installed: _________________________________________________________ Serial No.: _____________________________________________________________ Regency and Classic are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2005, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

C34-ng2

Table of Contents