Regency Classic F2400M Owners & Installation Manual

Regency Classic F2400M Owners & Installation Manual

Freestanding woodstove
Hide thumbs Also See for Classic F2400M:

Advertisement

Classic™ F2400M / S2400M
Owners &
Freestanding Woodstove
Installation Manual
www.regency-fire.com
French Manual: http://bit.ly/1myB2FA
F2400 Video
Manuel en Français: http://bit.ly/1myB2FA
MODELS:
F2400M
S2400M
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
919-542
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
02.26.16

Advertisement

Table of Contents
loading

Summary of Contents for Regency Classic F2400M

  • Page 1 Classic™ F2400M / S2400M Owners & Freestanding Woodstove Installation Manual www.regency-fire.com French Manual: http://bit.ly/1myB2FA F2400 Video Manuel en Français: http://bit.ly/1myB2FA MODELS: F2400M S2400M Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner.
  • Page 2 The following statements are required by the Environmental Protection Agency: “This manual describes the installation and operation of the Regency F2400 and S2400 wood heater. This heater meets the 2015 U.S. Environmental Pro- tection Agency’s crib wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 12,000 BTU/hr.
  • Page 3 Modular Parts F2400 Video Regency 2400 Freestanding Woodstove...
  • Page 4: Table Of Contents

    S2400m Step Stove Main Assembly w/classic door ..28 Stainless steel smoke deflector S2400m Step Stove Main Assembly w/contemporary door adjustment / replacement ..........19 Brick Installation ............20 Pedestal, Bottom Shield & Leg Options ......30 Classic Door Handle ............20 Firebrick ...............31 Warranty ..............35 Regency 2400 Freestanding Woodstove...
  • Page 5: Safety Label For F2400M

    À COMBUSTIBLE SOLIDE, CONVENANT AUSSI F2400M WITH AIRMATE SHIELD F2400M WITHOUT AIRMATE SHIELD POUR INSTALLATION DANS UNE MAISON MOBILE MEASURE FLUE MEASURE FLUE MODEL: REGENCY MEDIUM FREESTANDING STOVE - F2400M FROM HEATER CENTER-LINE FROM HEATER CENTER-LINE TESTED TO: UL-1482-2011 / ULC-S627-00 / UL-737-2011...
  • Page 6: Safety Label For S2400M

    DU CENTRE DU FROM HEATER CENTER-LINE A PARTIR DU POÊLE CONDUIT DE FUMÉE MODEL: REGENCY MEDIUM FREESTANDING STEP STOVE - S2400M RESIDENTIAL INSTALLATION USING INSTALLATION RÉSIDENTIELLE UTILISANT TESTED TO: UL-1482-2011 / ULC-S627-00 / UL-737-2011 REPORT NO:219-S-02-2 SINGLE WALL CONNECTOR UN CONNECTEUR À SIMPLE PAROI THE S2400M MEETS UL737 STANDARD FOR FIREPLACE STOVES WHEN A FIRESCREEN IS PROVIDED.
  • Page 7: F2400M Unit Dimensions

    F2400M UNIT DIMENSIONS Contemporary Door Classic Door Regency 2400 Freestanding Woodstove...
  • Page 8: S2400M Unit Dimensions

    S2400M UNIT DIMENSIONS Contemporary Door Classic Door Regency 2400 Freestanding Woodstove...
  • Page 9: Residential Installation

    WARNING: ONLY USE SPECIFIED COMPONENTS. The following items are required when assembling your Regency Stove. F2400 unit - the Rear Heat Deflector is supplied with the stove, but if you choose not to use it you must use the Airmate instead.
  • Page 10: Room Air

    6.5" (165 mm) 6" (152 mm) 27" (685 mm) 13" (330 mm) 17.5" (444mm) Medium S2400M Step Stove 15" (381 mm) 5.5" (139 mm) 4" (101 mm) 27" (685 mm) 12" (304 mm) 17" (432mm) 10 | Regency 2400 Freestanding Woodstove...
  • Page 11: Floor Protection

    Minimum Alcove Clearance and Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 84" Maximum depth of alcove - 36"...
  • Page 12: Stove Assembly Prior To Installation

    Note: Any paint touch up should be done prior to placing logo on pedestal. 5) If not using ash drawer, then cover plate must Diagram 3 be installed. If using ash drawer, then disregard cover plate. 12 | Regency 2400 Freestanding Woodstove...
  • Page 13: Step-By-Step Chimney And Connector Installation

    90 degrees. Pipe fresh air into the bottom shield by using a minimum 4" duct pipe with a mesh grill at the outside termination. At- Horizontal Installation tach the pipe to the 2 tabs with screws. Regency 2400 Freestanding Woodstove...
  • Page 14: Masonry Chimney

    "T" section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other obstructions for safety and proper draft operation. 14 | Regency 2400 Freestanding Woodstove...
  • Page 15: Combustible Wall Chimney Connector Pass-Throughs

    Cover opening with and support chimney section on both sides with 24 gage minimum sheet metal supports. See that the supports are fastened securely to wall surfaces on all sides. Make sure fasteners used to secure chimney flue liner. Regency 2400 Freestanding Woodstove...
  • Page 16: Recommended Heights For Woodstove Flue

    20.5 25.5 8000-9000 16.0 17.0 18.5 20.0 24.0 21.0 26.5 9000-10000 16.5 17.5 19.0 20.5 24.5 22.0 27.0 NOTE: No more than two offsets (four elbows) allowed. Two 45 elbows equal one 90 elbow. 16 | Regency 2400 Freestanding Woodstove...
  • Page 17: Mobile Home Installation

    11) WARNING: DO NOT INSTALL IN A SLEEPING ROOM OF A MOBILE HOME. 12) Use silicone to create an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure. Regency 2400 Freestanding Woodstove...
  • Page 18: Listed Components For Mobile Home Installation

    ICC EXCEL 2100 tap it into place with a hammer. A tighter fit The Regency F2400M and S2400M Freestand- Qty.Part # Description will ensure the tube will not move when the...
  • Page 19: Stainless Steel Smoke Deflector Adjustment / Replacement

    WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty. Ensure defector is seated so bolts are situated at the top of the keyhole before tightening. Hand tighten bolts only. Regency 2400 Freestanding Woodstove...
  • Page 20: Brick Installation

    Be careful of the edge clearances, (one inside the firebox and one on the maintain glass edge clearances. underside of the firebox) by remov- ing the two nuts and bolts holding the 2 plates together from inside the firebox. 20 | Regency 2400 Freestanding Woodstove...
  • Page 21: Screen Door

    (grounding) plug for your protection against shock hazard and should be plugged directly into a prop- erly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. Handle at 10 o'clock position. Regency 2400 Freestanding Woodstove...
  • Page 22: Seasoned Wood

    Two dry pieces banged together sound hollow; wet pieces sound solid and dull. • Dry wood weighs much less than wet wood. • Split a piece of wood. If the exposed surface feels damp, the wood is too wet to burn. 22 | Regency 2400 Freestanding Woodstove...
  • Page 23: Operating Instructions

    This procedure Regency Stove causing a draft down your drawn out of the fireplace stove opening, is for fire start-up only, as unit may chimney.
  • Page 24: Fan Operation

    It will also shut 7) Your Regency stove can be very hot. You may be the fan system off after the fire has gone out and seriously burned if you touch the stove while it is the unit cooled to below a useful heat output range.
  • Page 25: Maintenance

    DO NOT use abrasive If the door gasket requires replacement 7/8" diam- materials or chemical cleaners, as they may eter material must be used. Regency uses AMATEX harm the finish and void the warranty. When wood is burned slowly, it produces tar and # 10-863KR 7/8"...
  • Page 26: F2400M Stove Main Assembly W/Classic Door

    948-079 bn Spring Hinge Cap Nickel (each) 948-135 Spring Handle - Large Nickel 948-136 Spring Handle - Small Nickel INSTALL EITHER "AIR MATE" OR "REAR AIR DEFLECTOR" MAIN ASSEMBLY BLOWER/FAN (OPTION) SCREEN DOOR (OPTION) 26 | Regency 2400 Freestanding Woodstove...
  • Page 27: F2400M Stove Main Assembly W/Contemporary Door

    820-482 Smoke Deflector Nut - 1/4 - 20 Hex 846-570 7/8" Door Gasket Repair Kit 918-154 Manual 948-082 Hinge Cap Black (each) 156-241 Cast Handle *Not available as a replacement part. 948-144 Small Spring Handle Black Regency 2400 Freestanding Woodstove...
  • Page 28: S2400M Step Stove Main Assembly W/Classic Door

    Door Handle Assembly 919-542 Manual 846-570 7/8" Door Gasket Repair Kit 948-079 BN Hinge Cap Nickel (each) *Not available as a replacement part. 948-135 Spring Handle - Large Nickel 948-136 Spring Handle - Small Nickel 28 | Regency 2400 Freestanding Woodstove...
  • Page 29: S2400M Step Stove Main Assembly W/Contemporary Door

    Door Handle Assembly 846-570 7/8" Door Gasket Repair Kit 846-918 Hinge Caps - Gold (2/set) 919-542 Manual 948-082 Hinge Cap Black (each) 156-241 Cast Handle *Not available as a replacement part. 948-144 Small Spring Handle Black Regency 2400 Freestanding Woodstove...
  • Page 30: Pedestal, Bottom Shield & Leg Options

    Ashdrawer - Bottom Shield 942-110 Ash Plug 820-249 Ash Plug Tool Handle 140) 850-126 Legs - Cast Black 850-128 Legs - Cast Brush Nickel 948-223 Regency Logo - Nickel 919-542 Manual *Not available as a replacement part. 30 | Regency 2400 Freestanding Woodstove...
  • Page 31: Firebrick

    70) Brick - Regular Full Size: 1-1/4" x 4-1/2" x 9" 72) Brick Partial: 1-1/4" x 2" x 4-1/2" 74) Brick Partial: 1-1/4" x 4-1/2" x 3-1/2" 76) Brick Partial: 1-1/4" x 2" x 9" 919-598 10/06/15 Regency 2400 Freestanding Woodstove...
  • Page 32 32 | Regency 2400 Freestanding Woodstove...
  • Page 33 Regency 2400 Freestanding Woodstove...
  • Page 34 34 | Regency 2400 Freestanding Woodstove...
  • Page 35: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-field service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 36 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ F2400 Video Regency and Classic are trademarks of FPI Fireplace Products International Ltd. © Copyright 2016, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

Classic s2400m

Table of Contents