C34 Classic™ Direct Vent Owners & Freestanding Gas Stove Installation Manual C34 Video www.regency-fire.com MODELS: C34-NG10 Natural Gas C34-LP10 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
Page 2
REGENCY Classic Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Stove by Fireplace Products International Ltd. The Regency Gas Series ® of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the flick of a switch.
Page 3
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Intertek as a Direct Vent Room Heater to the following standards: CAN/CGA-2.17-M91,ANSI Z21.88- ® 2014 • CSA 2.33-2014. This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
Page 4
ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Burner Assembly & Log Set ........39 High Elevation ..............28 Base Options ...............40 Gas Pipe Pressure Testing ..........28 Log Installation ............30 Warranty Door and Glass Frame ..........30 Safety screen installation / removal ......31 Warranty ..............42 Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Page 6
This is a copy of the label that accompanies NOTE: Regency units are constantly being ® each CLASSIC Direct Vent Freestanding Gas improved. Check the label on the unit and if Stove. We have printed a copy of the contents there is a difference, the label on the unit is here for your review.
Page 7
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
IF THE BARRIER BECOMES DAMAGED, SURFACE TEMPERATURES, ESPE- THE BARRIER SHALL BE REPLACED CIALLY THE FIREPLACE GLASS, AND WITH THE MANUFACTURER'S BARRIER SHOULD STAY AWAY TO AVOID BURNS FOR THIS APPLIANCE. OR CLOTHING IGNITION. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
- WARNING - Risk of fire or electric shock. Only qualified service personnel shall be used to install and provide mainte- nance of this appliance. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
2. Ensure proper grounding using the #8 ground Side wall lug provided. See "Optional Fan Installation" section. 3. Appliance must be anchored to the floor. See "Pedestal Assembly" & "Leg and Bottom" sections. 10 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
5. Place the fan assembly partially in door cover plate hole. See Diagram 4. 6. Attach the 2 ground wires (green) to the ground lug as per Diagram 4. Diagram 7 919-512a 09.16.16 Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Page 12
(Diagram 5). 7. Turn fan 90 degrees. (Diagram 5). (Pedestal units only). 8. Disconnect the green ground wires to the grounding lug. Remove fan from stove. (Diagram 3) 09.16.16 919-512a 12 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Tighten the bolts. 3. Push the Regency® logo into the two holes in the front bottom left corner 3. Level the stove by adjusting the levelling of the pedestal cover plate.
1. Wear gloves and safety glasses for protection. 2. Exercise extreme caution when using ladders or on roof tops. 3. Be aware of electrical wiring locations in walls and ceilings. 14 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
* Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: The listed manufacturers may have other lengths not shown on this chart, which would also be approved.
Page 17
Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove...
, Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products ® International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. 18 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Offset to Vertical Vent. A 15 ft. vertical run with 4 ft. horizontal offset distance falls within the shaded area and is an allowable installation with Vent Restrictor Position "R" (Right). Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Page 20
90 elbows is 5' Min. 8' Max. 6' Min. required. Lengths do not include elbow indicated. Vent restrictor position C (fully open), refer to "Vent Restrictor Position" section 20 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
When using snow blowers, make sure snow is not directed towards vent termination area. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Page 22
4" dia. flex liner. stainless steel). Note: pilot holes will need to be drilled through the wall thimble on all 12. Install the spring spacers onto the pipe 4 corners. sections. 22 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Secure Vent , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products ® International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Diagram 1 Horizontal Termination. NEVER install the snorkel upside down. b) Horizontal runs of vent must be sup- ported every three feet. Wall straps are available for this purpose. 24 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Canada). the vent pipe every 3 feet, to avoid exces- sive stress on the elbows, and possible separation. Wall straps are available for this purpose. See Diagram 9. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
2. Place the support in the opening. Lower it to the 6. Twist lock the vent cap on to the last section. correct height as determined by the table and Diagram below. 26 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
If the appliance shuts off during operation, contact a qualified service person to determine if a negative pressure and/or leaky chimney condition exists. Do not operate the appliance until the problem is corrected. Diagram 1 Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
(clockwise) with a 1/8" flat screwdriver. Screw should be snug, but do not over tighten. 28 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Page 29
DC Sparker Box by opening the battery 8. Main Gas Outlet compartment. 9. Alternative TC Connection Point NOTE: The battery in the DC Sparker Box will need to be replaced annually. Pedestal base shown Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
The flat side of the log other. (Use Extreme Caution and ensure facing the back of the unit. Carefully push proper light off of burner.) the log down onto the pins. See Diagram 3. 30 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Thermostat (CP-2 System) 3. To remove the safety screen, lift up slightly and Wire Size Max. Length pull forward. Use the Regency Remote Control Kit supplied ® 14 GA. 50 Ft. with this unit. Use of other systems may void your 16 GA.
Note: Aeration Adjustment should only be a bluer flame. The burner aeration is factory set performed by an authorized Regency Note: If you have an incorrect flame pattern, but may need adjusting due to either the local ®...
7. The unit should never be turned off, and on again without a minimum of a 60 second wait. Diagram 1 34 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Mettre le bouton de contrôle de gaz sur ''OFF'' pour éteindre la veilleuse. Pour économiser le carburant, éteindre la veilleuse quand l’appareil reste longtemps inutilisé. DO NOT REMOVE THIS INSTRUCTION PLATE 919-456 Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
In the event that you break your glass by 17. Remove inlet pipe with pipe wrench. Note impact, purchase your replacement glass from an orientation of 90o elbow. authorized Regency ® dealer only. 18. Remove two (2) phillips head M5 screws on each side of the valve.
Air Baffle Plate Capscrew 1/4 x 1-3/4" NC Upper Air Passage Assembly 490-081 Flue Restrictor 490-520 Top Assembly 490-042 Rear Panel 919-490 Manual *Not available as a replacement part. 38 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
Deflector-Top Rear Log - NG 490-068 Deflector-Top Rear Log - LP 490-932 Complete Log Set 902-151 Ember 902-153 Rockwool 904-537 Gas Inlet Pipe (12") Not available as a replacement part Not shown Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
BASE OPTIONS Part # Description Part # Description 948-216 Regency® Logo 493-921 Complete Floor Shield 102. 904-257 Magnetic Catch (Large) 948-216 Regency ® Logo 103. 11" Pedestal Hinge 102. 904-257 Magnetic Catch (Large) 910-327 Strain Relief for Power Cord 103.
Page 41
Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: December 2016 Regency Gas Products Warranty 42 | Regency CLASSIC™...
Page 43
Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: December 2016 Regency Gas Products Warranty Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove...
Page 44
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
Page 45
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.