C34 Classic™ Direct Vent
Freestanding Gas Stove
MODELS:
C34-NG10 Natural Gas
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
919-490d
C34-LP10 Propane
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
C34 Video
www.regency-fire.com
07.23.18

Advertisement

Table of Contents
loading

Summary of Contents for Regency Classic C34 Series

  • Page 1 C34 Classic™ Direct Vent Owners & Freestanding Gas Stove Installation Manual C34 Video www.regency-fire.com MODELS: C34-NG10 Natural Gas C34-LP10 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2 REGENCY Classic Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Stove by Fireplace Products International Ltd. The Regency Gas Series ® of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the flick of a switch.
  • Page 3 INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Intertek as a Direct Vent Room Heater to the following standards: CAN/CGA-2.17-M91,ANSI Z21.88- ® 2014 • CSA 2.33-2014. This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
  • Page 4 ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 5: Table Of Contents

    Burner Assembly & Log Set ........39 High Elevation ..............28 Base Options ...............40 Gas Pipe Pressure Testing ..........28 Log Installation ............30 Warranty Door and Glass Frame ..........30 Safety screen installation / removal ......31 Warranty ..............42 Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 6 This is a copy of the label that accompanies NOTE: Regency units are constantly being ® each CLASSIC Direct Vent Freestanding Gas improved. Check the label on the unit and if Stove. We have printed a copy of the contents there is a difference, the label on the unit is here for your review.
  • Page 7 (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 8: For Your Safety

    IF THE BARRIER BECOMES DAMAGED, SURFACE TEMPERATURES, ESPE- THE BARRIER SHALL BE REPLACED CIALLY THE FIREPLACE GLASS, AND WITH THE MANUFACTURER'S BARRIER SHOULD STAY AWAY TO AVOID BURNS FOR THIS APPLIANCE. OR CLOTHING IGNITION. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 9: Important Message

    - WARNING - Risk of fire or electric shock. Only qualified service personnel shall be used to install and provide mainte- nance of this appliance. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 10: Installation Checklist

    2. Ensure proper grounding using the #8 ground Side wall lug provided. See "Optional Fan Installation" section. 3. Appliance must be anchored to the floor. See "Pedestal Assembly" & "Leg and Bottom" sections. 10 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 11: Optional Fan Installation

    5. Place the fan assembly partially in door cover plate hole. See Diagram 4. 6. Attach the 2 ground wires (green) to the ground lug as per Diagram 4. Diagram 7 919-512a 09.16.16 Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 12 (Diagram 5). 7. Turn fan 90 degrees. (Diagram 5). (Pedestal units only). 8. Disconnect the green ground wires to the grounding lug. Remove fan from stove. (Diagram 3) 09.16.16 919-512a 12 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 13: Pedestal Assembly

    Tighten the bolts. 3. Push the Regency® logo into the two holes in the front bottom left corner 3. Level the stove by adjusting the levelling of the pedestal cover plate.
  • Page 14: Venting Introduction

    1. Wear gloves and safety glasses for protection. 2. Exercise extreme caution when using ladders or on roof tops. 3. Be aware of electrical wiring locations in walls and ceilings. 14 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 15: Exterior Vent Terminal Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 16: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    ” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: The listed manufacturers may have other lengths not shown on this chart, which would also be approved.
  • Page 17 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove...
  • Page 18: Rigid Pipe Venting Systems

    , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products ® International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. 18 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 19: Venting Arrangements

    Offset to Vertical Vent. A 15 ft. vertical run with 4 ft. horizontal offset distance falls within the shaded area and is an allowable installation with Vent Restrictor Position "R" (Right). Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 20 90 elbows is 5' Min. 8' Max. 6' Min. required. Lengths do not include elbow indicated. Vent restrictor position C (fully open), refer to "Vent Restrictor Position" section 20 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 21: Dv Stove Horizontal Vent Kit

    When using snow blowers, make sure snow is not directed towards vent termination area. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 22 4" dia. flex liner. stainless steel). Note: pilot holes will need to be drilled through the wall thimble on all 12. Install the spring spacers onto the pipe 4 corners. sections. 22 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 23: Dura-Vent Termination Kit

    Secure Vent , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products ® International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 24: Dura-Vent Horizontal Installations

    Diagram 1 Horizontal Termination. NEVER install the snorkel upside down. b) Horizontal runs of vent must be sup- ported every three feet. Wall straps are available for this purpose. 24 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 25: Vertical Termination

    Canada). the vent pipe every 3 feet, to avoid exces- sive stress on the elbows, and possible separation. Wall straps are available for this purpose. See Diagram 9. Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 26: Cathedral Ceilings

    2. Place the support in the opening. Lower it to the 6. Twist lock the vent cap on to the last section. correct height as determined by the table and Diagram below. 26 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 27: Direct Vent System

    If the appliance shuts off during operation, contact a qualified service person to determine if a negative pressure and/or leaky chimney condition exists. Do not operate the appliance until the problem is corrected. Diagram 1 Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 28: System Data

    (clockwise) with a 1/8" flat screwdriver. Screw should be snug, but do not over tighten. 28 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 29 DC Sparker Box by opening the battery 8. Main Gas Outlet compartment. 9. Alternative TC Connection Point NOTE: The battery in the DC Sparker Box will need to be replaced annually. Pedestal base shown Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 30: Log Installation

    The flat side of the log other. (Use Extreme Caution and ensure facing the back of the unit. Carefully push proper light off of burner.) the log down onto the pins. See Diagram 3. 30 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 31: Safety Screen Installation / Removal

    Thermostat (CP-2 System) 3. To remove the safety screen, lift up slightly and Wire Size Max. Length pull forward. Use the Regency Remote Control Kit supplied ® 14 GA. 50 Ft. with this unit. Use of other systems may void your 16 GA.
  • Page 32: Wiring Diagram

    Do not cut or remove the grounding prong from this plug. 32 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 33: Pilot Adjustment

    Note: Aeration Adjustment should only be a bluer flame. The burner aeration is factory set performed by an authorized Regency Note: If you have an incorrect flame pattern, but may need adjusting due to either the local ®...
  • Page 34: First Fire

    7. The unit should never be turned off, and on again without a minimum of a 60 second wait. Diagram 1 34 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 35: Copy Of The Lighting Plate Instructions

    Mettre le bouton de contrôle de gaz sur ''OFF'' pour éteindre la veilleuse. Pour économiser le carburant, éteindre la veilleuse quand l’appareil reste longtemps inutilisé. DO NOT REMOVE THIS INSTRUCTION PLATE 919-456 Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 36: Normal Operating Sounds Of Gas Appliances

    It may resistant paint. Regency® uses Stove Brite be caused by having excessive lateral runs, Paint - Metallic Black #6309.
  • Page 37: Glass Gasket

    In the event that you break your glass by 17. Remove inlet pipe with pipe wrench. Note impact, purchase your replacement glass from an orientation of 90o elbow. authorized Regency ® dealer only. 18. Remove two (2) phillips head M5 screws on each side of the valve.
  • Page 38: Main Assembly

    Air Baffle Plate Capscrew 1/4 x 1-3/4" NC Upper Air Passage Assembly 490-081 Flue Restrictor 490-520 Top Assembly 490-042 Rear Panel 919-490 Manual *Not available as a replacement part. 38 | Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 39: Burner Assembly & Log Set

    Deflector-Top Rear Log - NG 490-068 Deflector-Top Rear Log - LP 490-932 Complete Log Set 902-151 Ember 902-153 Rockwool 904-537 Gas Inlet Pipe (12") Not available as a replacement part Not shown Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 40: Base Options

    BASE OPTIONS Part # Description Part # Description 948-216 Regency® Logo 493-921 Complete Floor Shield 102. 904-257 Magnetic Catch (Large) 948-216 Regency ® Logo 103. 11" Pedestal Hinge 102. 904-257 Magnetic Catch (Large) 910-327 Strain Relief for Power Cord 103.
  • Page 41 Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove ®...
  • Page 42: Warranty

    FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: December 2016 Regency Gas Products Warranty 42 | Regency CLASSIC™...
  • Page 43 Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: December 2016 Regency Gas Products Warranty Regency CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove...
  • Page 44 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 45 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 48 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ C34 Video Regency and Classic are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2018, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Classic c34-ng10Classic c34-lp10Classic c34

Table of Contents