9..Prixm.Box
Metering.FPC.unit
・ Remove.the.solder.bridges.
・ Take out the three screws (#514).
・ Remove the metering FPC unit (#B1008).
・ Remove the three springs (#515).
・ Take out the two screws (#683).
・ Remove the light measuring base plate unit (#B513).
Penta.FPC.unit
・ Disconnect.the.two.FPCs.
・ Remove the penta FPC unit (#B1020).
・ Remove the metering aperture (#518).
NICS
Remove.solder.
bridges.
#B1020
- D59・D7000 -
VBA29001-R.3814.A
#514×3
#B1008
#515×3
#683×2
#B513