Nikon D7000 Repair Manual page 158

Hide thumbs Also See for D7000:
Table of Contents

Advertisement

VBA29001-R.3814.A
Inspection.and.adjustment.of.X-position
【Not.up.to.standard】
With AF X-positioning tool (J63120), make the adjustment.
Steps
① Separate the front body from the rear body (by disassembling up to the stage on Page D32).
②.Loosen.the.screw.
③ With reference to the next page, choose the AF X-positioning tool (J63120) whose red-circled section (see
below) has the appropriate width.
④ Insert the tip section of the chosen AF X-positioning tool into the below (green-colored) gap.
⑤ Position the AF sensor unit (#B2163) in the direction of the arrow, and tighten the screw.
⑥.Mount.the.rear.body,.and.restore.to.the.former.state.
⑦.Check.the.X-position.
J63120
#B2163
Screw
- A91 ・ D7000 -
NICS