6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
No.
1
Fan Motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Heat exchanger temp. sensor (TCJ-sensor)
5
Louver motor
Parts name
Type
ype
RPG-240-25B
(-)
(-)
(-)
24BYJ48-ST, MSBPC20F04
- 17 -
Specification
AC 220~240V, 25W
10kΩ at 25°C
10kΩ at 25°C
10kΩ at 25°C
Output (Rated) 4 phase, DC12V