Firing Rates - Riello RS 310/EV MZ Installation, Use And Maintenance Instructions

Forced draught gas burners
Table of Contents

Advertisement

4.8

Firing rates

The MAXIMUM OUTPUT is chosen from within the diagram area
(Fig. 3).
The MINIMUM OUTPUT must not be lower than the minimum
limit of the diagram:
Model
RS 310/EV MZ
RS 410/EV MZ
RS 510/EV MZ
RS 610/EV MZ
Technical description of the burner
kW
600
800
800
820
Tab. G
RS 610/EV
RS 510/EV
RS 410/EV
RS 310/EV
Thermal power – kW
11
GB
The firing rate value (Fig. 3) has been obtained
considering an ambient temperature of 20 °C, an
atmospheric pressure of 1013 mbar (approx. 0 m
a.s.l.), and with the combustion head adjusted as
WARNING
shown on page 24.
20072010
Fig. 3
20081760

Advertisement

Table of Contents
loading