Page 2
We do assure you that all persons are regarded without discrim- ination and on an equal basis. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
..................Teaching in the actuator ....................... Installation ..........................Adjustment ..........................Operation ..........................Dimensions in mm ......................... Technical details ........................Safety characteristic data ......................Supplementary data ......................Radio approval.......................... Order reference ........................System ............................Accessories ..........................Operating Manual PSEN cs2.2n 1003367-EN-05...
Page 4
Contents EC declaration of conformity ....................UKCA-Declaration of Conformity ..................Operating Manual PSEN cs2.2n 1003367-EN-05...
PSEN cs2.2n Introduction Validity of documentation This documentation is valid for the product PSEN cs2.2n. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
If installed in other environments, measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to in- terference. Operating Manual PSEN cs2.2n 1003367-EN-05...
Disposal In safety-related applications, please comply with the mission time T in the safety-related characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSEN cs2.2n 1003367-EN-05...
Do not remove the connector's protective cap until you are just about to connect the unit. This will prevent potential contamination. Unit features Transponder technology for presence detection Pilz coding type: uniquely coded Dual-channel operation 2 safety outputs LED display for: –...
Black Do not connect Grey The wire colour also applies for the cable available from Pilz as an accessory. Connection to evaluation devices Make sure that the selected evaluation device has the following property: OSSD signals are evaluated through 2 channels with plausibility monitoring...
Page 12
PSEN cs2.2n Connection diagram, single connection Actuator Safety switch Evaluation device Suitable Pilz evaluation devices are, for example: PNOZelog for safety gate monitoring PNOZpower for safety gate monitoring PNOZsigma for safety gate monitoring PNOZ X for safety gate monitoring PNOZmulti for safety gate monitoring Configure the switch in the PNOZmulti Configurator with switch type 3.
The first actuator to be detected by the safety switch (see Intended use [ 6]) is taught in automatically as soon as it is brought into the response range. NOTICE No other actuator may be taught in once this actuator has been taught. Operating Manual PSEN cs2.2n | 13 1003367-EN-05...
Possible loss of the safety function by changing the release distance with non-flush installation Installing the safety switch non-flush within electrically or magnetically con- ductive material, the value for the assured release distance S can change. – Check the assured release distance S Operating Manual PSEN cs2.2n | 14 1003367-EN-05...
Operating distances may deviate if other arrangements are used. Note the maximum permitted lateral and vertical offset (see Operating distances [ Lateral and vertical offset [ 10]). Operating Manual PSEN cs2.2n | 15 1003367-EN-05...
"Safety Gate" LED lights up yellow: Actuator is within the response range Fault indicator: "POWER/Fault" LED lights up red: Error message. Remedy: Rectify fault and interrupt power supply. Dimensions in mm 21,5 M12x1 Operating Manual PSEN cs2.2n | 16 1003367-EN-05...
Actuator typ. 80 ms Actuator max. 150 ms Delay-on de-energisation Actuator typ. 40 ms Actuator max. 260 ms Risk time in accordance with EN 60947-5-3 260 ms Supply interruption before de-energisation 20 ms Operating Manual PSEN cs2.2n | 17 1003367-EN-05...
Page 18
Min. distance between safety switches 400 mm Sensor flush installation in accordance with EN 60947-5-2 yes, follow installation guidelines Connection type M12, 5-pin male connector Material Max. torque setting for fixing screws 1 Nm Operating Manual PSEN cs2.2n | 18 1003367-EN-05...
A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Operating Manual PSEN cs2.2n | 19 1003367-EN-05...
2) this product must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this product not expressly approved by Pilz may void the FCC authorization to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
20 m 630298 30 m 630297 PSEN cable M12-5af Angled, M12, 5-pin, socket Open cable 630347 630348 10 m 630349 30 m 630350 PDP67 F 8DI ION Decentralised input module IP67 for PNOZmulti 773600 Operating Manual PSEN cs2.2n | 21 1003367-EN-05...
Page 22
European Parliament and of the Council. 2006/42/EC on machines 2014/53/EC on radio equipment The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/ downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany...
Page 23
We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...