Figure 76. Installing a disk
The disk's active light flashes to reflect the disk's spin-up sequence.
5. If required, apply the Cache Tier license.
6. Run the storage add disks command to add the new SSDs to the Cache Tier.
#
storage add disks 2.9,2.10,2.11,2.12,2.13,2.14,2.15 tier cache
Checking storage requirements...done
Adding disk 2.9 to the cache tier...done
Updating system information...done
Disk 2.9 successfully added to the cache tier.
Checking storage requirements...done
Adding disk 2.10 to the cache tier...done
Updating system information...done
Disk 2.10 successfully added to the cache tier.
Checking storage requirements...done
Adding disk 2.11 to the cache tier...done
Updating system information...done
Disk 2.11 successfully added to the cache tier.
Checking storage requirements...done
Adding disk 2.12 to the cache tier...done
Updating system information...done
Disk 2.12 successfully added to the cache tier.
Checking storage requirements...done