DeVilbiss LUNA-MARKII-R-PLUS Operation Manual
DeVilbiss LUNA-MARKII-R-PLUS Operation Manual

DeVilbiss LUNA-MARKII-R-PLUS Operation Manual

Advertisement

Quick Links

Operation Manual
Important:Read and follow all instructions and SAFETY PRECAUTIONS before using this equipment
The gun body of this model is finished with special coating. Do not use the wire brush or metal spatula for
cleaning. Do not inscribe letters on the gun body. It may cause peeling off the coating to peel off.

MODELS

LUNA2 - R- Air Cap No. - Fluid Tip Size – Type of Feed (G:Gravity / S:Suction)
(Ex.): LUNA2-R-244PLS -1.3-G ← (Auto-Refinishing (LVMP) – No.244+ Air Cap - Size1.3mm - Gravity)

SPECIFICATIONS

Maximum Working Air Pressure: 0.69 MPa,
Chart.1
Air Cap No.
Part Number
1.0
244+
LUNA2-3-244PLS
245+
LUNA2-3-245PLS
246+
LUNA2-3-246PLS

PARTS LIST

Chart.2
Ref No.
Part Number
1 LUNA2-6
2 JJ-50-K5
3 Refer Chart.1
4 Refer Chart.3
5 LUNA2-7
6 LUNA-8-K5
7 LUNA2-35
8 LUNA2-BODY-G Gun Body (Gravity)
8 LUNA2-S-BODY Gun Body (Suction)
9 LUNA2-44
10 LUNA2-443
11 FUN-43
12 FUN-25-K5
13 LUNA2-12
14 Refer Chart.3
15 FUN-14-K5
16 LUNA2-13
17 FUN-463
18 FUN-11-K3
19 FUN-46-K10
20 FUN-45-K5
21 FUN-108
22 LUNA2-42
23 LUNA2-30
24 LUNA2-34
Note) Ref. No. 24 (LUNA2-34) is needed for Ref.10 (LUNA2- 443) installation. When removing it, be careful not to damage the
surface of seat where inserted. A damaged seat can lead to air leakage.
LUNA-MARKⅡ-R-PLUS GUN
Maximum Working Fluid Pressure: 0.69 MPa
Tip size(mm)
Feed
1.3
1.5
1.8
G
S
G
S
G
S
Description
Retaining Ring
Seat Kit of 5
Air Cap
Fluid Tip
Baffle
Gasket Kit of 5
Fluid Inlet
Pattern Valve
Valve Seal Kit
Air Valve
Valve Spring
Air Valve Bushing
Needle
Needle Spring Kit of 5
Adjusting Screw
Needle Packing (2 pcs.)
Packing Gland Kit of 3
E-ring Kit of 10
Bearing Stud Kit of 5
Trigger
Cheater Valve
Air Connector
Valve Seal Inserting Tool
LVMP (for Auto-Refinishing)
Air consumption
Pattern width
Gun inlet pressure
(mm)
215/min
240
0.2MPa
215/min
270
0.2MPa
230/min
200
0.2MPa
Qty
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Chart.3
1
Description
1
Size(mm)
1
1.0
1
1.3
1.5
1
1.8
1
1
1
Application
Fluid inlet Air inlet
Metallics,
Pearls
Clear Coats,
G1/4
G1/4
Solids
Primers
Fluid Tip
LUNA2-4-1.0
LUNA2-41-1.0
LUNA2-4-1.3
LUNA2-41-1.3
LUNA2-4-1.5
LUNA2-41-1.5
LUNA2-4-1.8
LUNA2-41-1.8
Weight
(g)
253
Needle

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LUNA-MARKII-R-PLUS and is the answer not in the manual?

Questions and answers

Summary of Contents for DeVilbiss LUNA-MARKII-R-PLUS

  • Page 1 LUNA-MARKⅡ-R-PLUS GUN Operation Manual LVMP (for Auto-Refinishing) Important:Read and follow all instructions and SAFETY PRECAUTIONS before using this equipment The gun body of this model is finished with special coating. Do not use the wire brush or metal spatula for cleaning.
  • Page 2 SAFETY PRECAUTIONS This manual contains information that is important for you to know and understand. This information relates to USER SAFETY and PREVENTING EQIPMENT PROBLEMS. Read and follow SAFETY PRECAUTIONS before using this equipment. FIRE OR EXPLOSION HAZARD 1. When spraying, adequate exhaust must be provided to keep air free of accumulations of flammable vapors which may cause fire or explosion.
  • Page 3 PREVENTIVE MAINTENANCE 1. Daily lubrication and cleaning is necessary to maintain the best condition of the gun. 2. To clean the gun body, wipe exterior with solvent dampened cloth. Do not submerge the gun body in solvent as any solids may get into the air passage and cause troubles. 3.
  • Page 4 SERVICE CHECKS Normal spray pattern problem Cause Correction Will not spray No pressure to gun. Check air and material lines. Adjusting Screw (16) not properly adjusted. Adjust. Improper spray pattern A,B - Material build up on the Air Cap or Fluid Tip. A,B - Clean the Air Cap or Fluid Tip.

This manual is also suitable for:

Luna2-3-244plsLuna2-3-245plsLuna2-3-246pls

Table of Contents