Agitation Adjustments - Cornelius - Follett Horizon Elite Harmony HCD E 710AHT Series Installation Instructions Manual

Table of Contents

Advertisement

3.5
Top preparation – LANCER
Lancer models only
• Remove protective tape
• Apply gaskets
3.6
Agitation adjustments – CORNELIUS
Cornelius models ED, DB, DF, IDC and FLAVOR FUSION
Adjust the agitation timer located on the Cornelius PC board to 1 second on, 1 hour off. Note: See
Cornelius manual or call Cornelius Technical Service at 1-800-238-3600 for more information.
HARMONY • TOP-MOUNT
3.5
3
MOTOR ON TIME:
SET TO 1 SECOND
2.5
2
2
HRS
1.5
MOTOR OFF TIME:
HRS
SET TO 1 HOUR
1
HR
self-contained
4
4.5
5
ON
TIME
1
1.5
OFF
TIME
2.5
3
HRS
HRS
30
10
MIN
MIN
E-BOARD AGITATOR TIMER