General Characteristics; Receipt And Site Selection - Tecnoware EXA PLUS 1000 User Manual

Table of Contents

Advertisement

2 General Characteristics

EXA PLUS has all the advanced features, which guarantee maximum reliability and safety:
All functions are controlled by a microprocessor, giving full guarantee of high reliability.
Output Voltage regulation through AVR (Automatic Voltage Regulation).
Overload protection both in normal mode and in battery mode.
High performance battery charger, which extends the battery medium life ensuring an optimal recharge.
Start up even if the electrical network is not available.
Automatic restart after an automatic shut down due to a low battery condition once the AC utility power
returns.
Adapts automatically to 50 or 60 Hz input frequency.
LCD display for the visualization of the Input and Output Voltage, Battery Level percentage, Load Level
percentage, functioning modes, alarm and fault conditions.
LCD display with timed backlight, which keeps it active for 1 minute. To reactivate it, it is sufficient to
act on any of the buttons on the front panel.
Acoustic signals of various kinds indicating functioning modes and alarm/fault condition.
Communication with the computer through USB interface.
USB charger ports.
Protects and filters the telephone line.
Fast swappable battery.
High efficiency
Maximum reliability
Smart design and easy to use

3 Receipt and site selection

Carefully remove the UPS from its packaging, and carry out a meticulous inspection. We recommend keeping the
original packaging in a secure place, in case you need to send the UPS for maintenance purposes. In case of
transport damage, notify the carrier and dealer immediately.
We recommend paying attention to the below points in order to choose a correct placement for your UPS:
The UPS is designed to operate in a protected environment (e.g. offices). We therefore recommend
installing it in a place with very little or no humidity, dust or smoke.
In all circumstances, see the "Technical Characteristics" chapter for environmental specifications and
check that the selected area meets these specifications.
During normal operation the UPS discharges a minimal amount of heat. So it is necessary to leave at least
20 cm of unobstructed space all around the UPS in order to keep it properly ventilated.
Do not obstruct ventilation holes.
Do not insert objects or pour liquids in the ventilation holes.
Do not rest any object on top of the UPS.
Do not keep liquids, flammable gases or corrosive substances near the unit.
Install the UPS on a properly tiled floor. Avoid the installation on a floor that is not tiled flat.
User's manual
4