Connecting A F3Sj-E To Various Controllers - Omron F3SJ-E P25 Series User Manual

Safety light curtain
Hide thumbs Also See for F3SJ-E P25 Series:
Table of Contents

Advertisement

Connecting a F3SJ-E to Various Controllers

 Connecting a F3SJ-E to a G9SA-301 Controller
+24 VDC
Power
Supply
0 V
A1
A2
T11
T12
K2
a
K1
K1
b
6
PE
T21
T23 T22
Model G9SA-301
Unblocked
Blocked
External test/lockout reset switch
(S1)
Interlock reset switch
(S2)
Emergency stop switch
(S3)
Safety output
K1,K2 N.O. contact
KM1,KM2 N.O. contact
K1,K2 N.C. contact
KM1,KM2 N.C. contact
Communication
line (+) (Gray)
Communication
line (-) (Pink)
12
22
Feedback loop
11
21
KM1
KM2
13
23
33
T31
T32
3
4
1
K1
K2
a
Control
2
b
Circuit
5
K2
A
B
14
24
34
KM1
KM2
Input/Output Circuit and Applications
- G9SA-301 settings
- Manual reset mode
- Using feedback loop
- Using emergency stop switch
KM1
KM2
*1
S3
M
41
1
2
3
4
*1 If an emergency stop switch is not used, connect safety output 1 to
JP
5
T12 terminal and safety output 2 to T23 directly.
6
S1
: External test/lockout reset switch
(connect to 0 V if a switch is not required)
S2
: Interlock reset switch
42
S3
: Emergency stop switch (force-opening contact) (A165E, A22E)
KM1, KM2 : Safety relay with force-guided contact (G7SA) or
magnetic contactor
M
: 3-phase motor
Wiring for auto reset mode
Feedback loop
KM 1
KM 2
T32
T31
A
B
E
F3SJ-E/B
99
User's Manual