Connecting A F3Sj-B To Two Muting Sensors - Omron F3SJ-E P25 Series User Manual

Safety light curtain
Hide thumbs Also See for F3SJ-E P25 Series:
Table of Contents

Advertisement

Connecting a F3SJ-B to Two Muting Sensors

F39-JD A-L
Communication
line (+) (Gray)
Communication
line (-) (Pink)
Muting
sensor
(PNP output)
Reflector
+24 VDC
Power
0 V
Supply
Unblocked
Blocked
Muting input 1
Muting input 2
Safety output
KM1, KM2, KM3, KM4 N.O. contact
KM1, KM2, KM3, KM4 N.C. contact
External indicator
F39-JD A-D
Feedback loop
ML
+24 V
A1
T11
T12 T21 T22
T31 T32 T33 Y1
Open
Open
Control circuit
A2
S14 S24
S34 S44 S54
L1
X1 X2
KM1 KM2
KM3 KM4
PLC, etc.
Motor controller
S1
(operation command)
S2
KM1 to KM4 : Safety relay with force-guided contact (G7SA) or magnetic contactor
M1, M2
ML
PLC
*1. Also used for override input.
*2. Under muting system, connect to 0 V as the external device monitoring cannot be used.
Input/Output Circuit and Applications
- F3SJ-B settings
- Muting system
- Does not use external device monitoring function
- G9SX-AD322-T15 settings
- Auto reset mode
- Using feedback loop
KM1
KM2
KM3
KM1
KM4
KM2
+24 V
AND
M1
T41 T42
Open Open
OFF
Model G9SX-AD322-T15
: External test switch (connect to 0 V if a switch is not required)
: Lockout reset switch (connect to 24 V if a switch is not required)
: 3-phase motor
: External indicator
: Programmable controller
(Used for monitoring -- not related to safety system)
Wiring for manual reset mode
Feedback loop
KM1
KM2
S3
KM3
KM4
+24 V
T31
T32 T33 Y1
S3 : Reset switch
S34
Motor controller
KM3
KM4
M2
E