ABB UNO-DM-3.3-TL-PLUS Product Manual page 126

Hide thumbs Also See for UNO-DM-3.3-TL-PLUS:
Table of Contents

Advertisement

Vin > Vstart
N.C.
Relay State: Switched
N.O.
Vin < Vstart
N.C.
Relay State: Idle
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Idle
N.O.
Vin
Yes
No
IS STILL LESS THAN
Vstart
INVERTER RUN
N.C.
Relay State: Idle
N.O.
ERROR OCCURENCY
ERROR MESSAGE
t=15s
N.C.
Relay State: Switched
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Switched
N.O.
ERROR
Yes
No
STILL
PRESENT
• Crepuscolar - display text "Alarm-Contact (crepuscolar)":
The relay is activated (status: switched) as soon as the inverter input
voltage exceeds the activation voltage set.
The relay switch to rest position when the input voltage drops below 70%
of the activation voltage set.
This mode is useful for disconnecting any output transformers that could
have unnecessary consumption during the night.
• Alarm Latch - display text "Alarm-Contact (alarm ALL - latch)":
The relay is activated (status: switched) whenever an error (code Exxx)
or a warning (code Wxxx) is present (see the table below). When the in-
verter returns to the normal operating state and reconnects with the grid,
the contact returns to its position of rest.
Alarms for which the relay is activated
E001
E002
E007
E009
E014
E015
E020
E021
E026
E027
E032
E033
E046
E050
E057
E058
E089
W003
If the alarm condition is persistent, the relay will remain activated
(status:switched)
- 126 -
E003
E004
E005
E010
E011
E012
E016
E017
E018
E022
E023
E024
E028
E029
E030
E034
E035
E036
E053
E054
E055
E077
E078
E081
W004
W005
W006
7 - Operation
E006
E013
E019
E025
E031
E037
E056
E084
W007