National Instruments NI 5762 User Manual And Specifications

National Instruments NI 5762 User Manual And Specifications

Advertisement

Quick Links

NI-5762

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments NI 5762

  • Page 1 NI-5762...
  • Page 2: Table Of Contents

    NI 5762 (-02): Single-ended, AC-coupled, ideal for undersampling applications Read the white labels on the side of your device to determine which version of the NI 5762 you are using. This document contains signal information and specifications for the NI 5762R, which is composed of an NI FlexRIO FPGA module and the NI 5762.
  • Page 3: Electromagnetic Compatibility Guidelines

    Caution To ensure the specified EMC performance, you must install PXI EMC Filler Panels (National Instruments part number 778700-01) in adjacent chassis slots. For more information about installing PXI EMC filler panels on your NI 5762R, refer to the Appendix: Installing EMI Controls section of this document.
  • Page 4: How To Use Your Ni Flexrio Documentation Set

    Other Useful Information on ni.com ni.com/ipnet Contains LabVIEW FPGA functions and intellectual property to share. Contains product information and data sheets for NI FlexRIO devices. ni.com/flexrio These documents are also available at ni.com/manuals. © National Instruments Corporation NI 5762R User Guide and Specifications...
  • Page 5: Front Panel And Connector Pinouts

    Front Panel and Connector Pinouts Table 2 shows the front panel connectors and signal descriptions for both versions of the NI 5762. Refer to the Specifications section of this document for additional signal information. Caution To avoid permanent damage to the NI 5762, disconnect all signals connected to the NI 5762 before powering down the module, and connect signals only after the adapter module has been powered on by the NI FlexRIO FPGA module.
  • Page 6 The AUX I/O connector accepts a standard, third-party HDMI cable, but the AUX I/O port is not an HDMI interface. Do not connect the AUX I/O port on the NI 5762 into the HDMI port of another device. NI is not liable for any damage resulting from such signal connections.
  • Page 7: Block Diagram

    Block Diagram Figure 3 shows a block diagram image of the signal flow to and from the NI 5762 adapter module and the NI 5762 component-level intellectual property (CLIP) in LabVIEW FPGA. NI 5762 Adapter Module LabVIEW FPGA CLIP ADC Data...
  • Page 8: Ni 5762 Component-Level Intellectual Property (Clip)

    NI 5762 Component-Level Intellectual Property (CLIP) The LabVIEW FPGA Module includes a feature for HDL IP integration called CLIP. NI FlexRIO devices support two types of CLIP: user-defined and socketed. • User-defined CLIP allows users to insert HDL IP into an FPGA target, enabling VHDL code to communicate directly with an FPGA VI.
  • Page 9 The NI 5762 ships with socketed CLIP items that are used to add module I/O to the LabVIEW project. The NI 5762 ships with the following CLIP items: • NI 5762 Multiple Sample CLIP—This CLIP generates two samples per clock cycle at a clock rate that is half the sample rate.
  • Page 10: Cables

    Clocking The NI 5762 clocks control the sample rate and other timing functions on the device. Table 4 contains information about the possible NI 5762 clock resources. For more clocking information, refer to the CLK IN section of the specifications.
  • Page 11 Complete the following steps to run an example that acquires a waveform on AI 0 of the NI 5762. Connect one end of an SMA cable to AI 0 on the front panel of the NI 5762 and the other end of the cable to your device under test (DUT).
  • Page 12: Creating A Labview Project And Running A Vi On An Fpga Target

    Figure 5. NI 5762 - Getting Started (Host) VI Front Panel Creating a LabVIEW Project and Running a VI on an FPGA Target This section explains how to set up your target and create an FPGA VI and host VI for data communication.
  • Page 13 10. Right-click IO Module in the Project Explorer window and select Properties. 11. Select the NI 5762 (-0x) (where x corresponds with the NI part number of your device) from the IO Module list. The available CLIP for the NI 5762 is displayed in the General category of the Component Level IP pane.
  • Page 14 While Loop on the block diagram. 17. Wire the FPGA VI Reference Out terminal of the Read/Write Control function to the FPGA VI Reference In terminal of the Close FPGA VI Reference function. © National Instruments Corporation NI 5762R User Guide and Specifications...
  • Page 15 19. Save the VI as 5762SampleAcq(Host).vi Running the Host VI Connect one end of an SMA cable to AI 0 on the front panel of the NI 5762 and the other end of the cable to your DUT. Open the front panel of 5762SampleAcq(Host).vi...
  • Page 16: Specifications

    Specifications This section lists the specifications for both the NI 5762 (-01) and NI 5762 (-02) adapter modules. Pair these specifications with the specifications listed in the NI FlexRIO FPGA Module Installation Guide and Specifications. For more information about safety and electromagnetic compatibility refer to the...
  • Page 17 Absolute maximum voltage ........±3 V DC, 5 V pk-pk Table 5. Bandwidth (3 dB) Device Lower 3 dB Frequency Upper 3 dB Frequency NI 5762 (-01) 61.7 kHz 102 MHz NI 5762 (-02) 61.7 kHz Refer to Figures 8 and 10.
  • Page 18 –1 –2 –3 –4 –5 NI 5762 (-01) –6 80 90 100 110120 Frequency (MHz) Figure 9. Frequency Response, NI 5762 (-01) only (Logarithmic Scale) –2 –4 –6 –8 –10 –12 –14 –16 NI 5762 (-02) –18 0.6 0.7 0.8 0.9 1.0 Frequency (GHz) Figure 10.
  • Page 19 –20 –30 –40 –50 –60 –70 –80 –90 –100 –110 –120 –130 Frequency (MHz) Figure 12. Single-Tone Spectrum at 20 MHz, –3.1 dBFS, SFDR –90.8 dBc, NI 5762 (-01) and NI 5762 (-02) NI 5762R User Guide and Specifications ni.com...
  • Page 20 Table 6. Spectral Performance NI 5762 (-01) NI 5762 (-02) Measurement Power Result Power Result SNR at 10.1 MHz –1 dBFS 74.6 dBc –1 dBFS 75.8 dBc SINAD at 10.1 MHz –1 dBFS 73.3 dBc –1 dBFS 75.2 dBc SFDR at 10.1 MHz –6 dBFS...
  • Page 21 –80.0 –85.0 –90.0 –95.0 –100.0 –105.0 –110.0 –115.0 –120.0 –125.0 –130.0 –135.0 –140.0 –145.0 –150.0 –155.0 100k Frequency Offset from Carrier (Hz) Figure 14. Analog Input Phase Noise with 100 MHz Input Signal, PLL Off Internal Sample Clock Clock distribution part number ......AD9511 Oscillator type............VCXO Frequency...............250 MHz Phase noise...
  • Page 22 ..........0.4 V Minimum V ..........2.7 V Maximum V ..........3.6 V ..............50 Ω ± 20% (DC)............±2 mA Pull-down resistor ..........150 kΩ Recommended operating voltage......–0.3 V to 3.6 V Overvoltage protection...........±10 V © National Instruments Corporation NI 5762R User Guide and Specifications...
  • Page 23 Product ID Serial Number Reserved 0x7C User Space Caution Only write to User Space. Writing to any other offset may cause the NI 5762 to stop functioning. Power Total power, typical operation........5.3 W Physical Dimensions ............12.9 × 2.0 × 12.1 cm (5.1 ×...
  • Page 24 To obtain product certifications and the Declaration of Conformity for this product, visit ni.com/ , search by model number or product line, and click the appropriate link in the certification Certification column. © National Instruments Corporation NI 5762R User Guide and Specifications...
  • Page 25: Where To Go For Support

    National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/...
  • Page 26: Appendix: Installing Emi Controls

    NI 5762R system. Your kit includes two HDMI cable ferrites, but PXI EMC filler panels (National Instruments part number 778700-01) must be purchased separately. For more installation information, refer to the NI FlexRIO FPGA Module Installation Guide and Specifications.
  • Page 27 For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. Refer to the Export Compliance Information at ni.com/legal/ export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data.

This manual is also suitable for:

Ni 5762-01Ni 5762-02Ni 5762r

Table of Contents