Siemens APOGEE P1
Communications Option
Technical Manual
HA470909 Issue 3
Compatible with Version 1.x Software
© Copyright 2010 Parker Hannifin Ltd.
All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any
form or by any means to persons not employed by a Parker Hannifin Ltd., Automation Group, SSD Drives
Europe without written permission from Parker Hannifin Ltd., Automation Group, SSD Drives Europe. Although
every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to
make amendments or correct omissions. Parker Hannifin ltd., Automation Group, SSD Drives Europe cannot
accept responsibility for damage, injury, or expenses resulting there from.
Parker Hannifin Ltd., Automation Group, SSD Drives Europe, warrants the goods against defects in design, materials
and workmanship for the period of 24 months from the date of manufacture, or 12 months from the date of delivery
(whichever is the longer period) on the terms detailed in Parker SSD Drives Standard Conditions of Sale IA500504.
Parker Hannifin Ltd., Automation Group, SSD Drives Europe reserves the right to change the content and product
WARRANTY
specification without notice.

Advertisement

Table of Contents
loading

Summary of Contents for Parker Siemens APOGEE P1

  • Page 1 All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any form or by any means to persons not employed by a Parker Hannifin Ltd., Automation Group, SSD Drives Europe without written permission from Parker Hannifin Ltd., Automation Group, SSD Drives Europe. Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions.
  • Page 2 Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized...
  • Page 3 Safety Information Requirements IMPORTANT: Please read this information BEFORE installing the equipment. Intended Users This manual is to be made available to all persons who are required to install, configure or service equipment described herein, or any other associated operation. The information given is intended to highlight safety issues, EMC considerations, and to enable the user to obtain maximum benefit from the equipment.
  • Page 4 Safety Information Hazards DANGER! - Ignoring the following may result in injury 1. This equipment can endanger life by exposure to 5. For measurements use only a meter to IEC 61010 rotating machinery and high voltages. (CAT III or higher). Always begin using the highest range.
  • Page 5: Table Of Contents

    Wiring Diagrams......................5 Initial Check for Connection ..................6 Understanding the LED Indications................6 Initial Set-up for APOGEE P1................8 Configuring the Drive....................8 Troubleshooting..................... 10 Point Database for Siemens APOGEE P1 ..............11 Point Database Cross Reference................13 Cont.5...
  • Page 7: Siemens Apogee P1 Option

    Protocol This card communicates using the Siemens APOGEE P1 protocol. Any connections made to it most comply with this protocol. Every effort has been made to maintain compatibility with devices using this protocol.
  • Page 8: Installation

    Wiring is very simple - all connections are SELV (Safe Extra Low Voltage). It is possible to establish serial communications without adhering to the following recommendations, however, the recommendations will promote greater reliability. Consult with the Siemens Building Technology office for information on wiring and Note: cabling. Siemens APOGEE P1 Communications Interface...
  • Page 9: User Connections To The Main Serial Port (P1)

    Status Description Switch SW1 unused 2-wire (default) Terminator out (default) Terminator in All units in the system must have switch 2 set to OFF. Siemens personnel will add Note: terminators if needed to the FLN. Siemens APOGEE P1 Communications Interface...
  • Page 10: Terminal Block (Tb1) Connections

    Option. On the SIZE 1 unit it will protrude slightly above the standard plastic enclosure. • Make all user wiring connections. Refer to the Wiring Diagrams. • Re-fit the terminal cover securely with the screws. Siemens APOGEE P1 Communications Interface...
  • Page 11: Wiring Diagrams

    Figure 3 2-Wire Wiring Diagram for the HVAC10 Size 2 & 3 Drive DRIVE DRIVE (slave) (slave) APOGEE Controller FL1, FL2 or FL3 connections 0V SCR 0V SCR Figure 4 2-Wire Wiring Diagram for the HVAC10 Size 1 Drive Siemens APOGEE P1 Communications Interface...
  • Page 12: Initial Check For Connection

    Module LED Indication FAULT Parameter Indication Description SELF TEST Initialising SHORT FLASH HARDWARE Hardware fault FLASH TYPE MISMATCH Wrong type or disabled LONG FLASH PARAMETER Set-up fault, parameter values out-of-range NONE Valid set-up, ready for external communications Siemens APOGEE P1 Communications Interface...
  • Page 13 SOFT TIMEOUT: Drive not addressed in the last 10 seconds. OK: Device has been addressed. Note: The NETWORK LED can only be in the ON state when the MODULE LED is ON continuously, indicating that the Option is ready for external communications. Siemens APOGEE P1 Communications Interface...
  • Page 14: Initial Set-Up For Apogee P1

    MMI if no Technology Option is fitted or an incorrect TYPE is selected for the fitted TEC OPTION Technology Option. TYPE DSE Lite is Parker SSD Drives’ Windows-based block programming software. INPUT 1 INPUT 2 When the TYPE parameter is set to display RS485, the function block parameters take on new INPUT 3 identities, as shown in the lower Function Block diagram.
  • Page 15 5 : DISABLED Serial communication has been disabled (default) Also refer to Network LED, page 7. NIGHT Range: FALSE/TRUE Shows the Night occupancy set by the FLN P1 network. Siemens APOGEE P1 Communications Interface...
  • Page 16: Troubleshooting

    Check that switch SW1:1 is ON, i.e. selected for 2- wire operation. Check power for all equipment on the network, e.g. RS232 to RS485 converter or repeater. SOFT TIMEOUT: Check the APOGEE controller program is running. Drive not addressed in the last 10 seconds. Siemens APOGEE P1 Communications Interface...
  • Page 17: Point Database For Siemens Apogee P1

    Point Database for Siemens APOGEE P1 Point Point Subpoint Name Factory Default Engr. Units Slope Intercept On Text Off Text Number Type (SI Units) (SI Units) (SI Units) (SI Units) CTRL ADDRESS ED_HVAC10 2731 Freq Output Freq Demand Speed Current -1638.3...
  • Page 18 Point Database for Siemens APOGEE P1 cont. Analog 1 Out 0.01 -163.83 Analog 2 Out 0.01 -163.83 Analog 3 Out 0.01 -163.83 Analog In 1 0.01 -163.83 Analog In 2 0.01 -163.83 Analog In 3 0.01 -163.83 Analog In 4 0.01...
  • Page 19: Point Database Cross Reference

    Setup/Motor Control/Flycatching/Enable Flycatching Setup/Motor Control/Flycatching/Active Analog 1 Out Setup/Inputs & Outputs/An Out/An Out 1/Value Analog 2 Out Setup/Inputs & Outputs/An Out/An Out 2/Value Analog 3 Out Setup/Inputs & Outputs/An Out/An Out 3/Value continued on next page… Siemens APOGEE P1 Communications Interface...
  • Page 20 Skip Freq 4 Startup/Setpoint Funcs/Skip Frequencies/Freq 4 Band 4 Startup/Setpoint Funcs/Skip Frequencies/Band 4 AR Enable Setup/Seq & Ref/Auto Restart/Enable AR attempts Setup/Seq & Ref/Auto Restart/Attempts AR Delay Setup/Seq & Ref/Auto Restart/Attempt Delay 1 Error Status Siemens APOGEE P1 Communications Interface...