Page 2
For quick future reference, fill in the unit information in the spaces below. Should you need assistance, call the Parker Hannifin customer service number shown below. To expedite your service, have the following information available when contacting Parker Hannifin.
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models SAFETY PRECAUTIONS We have provided many important safety messages in this manual and on the PCN Electrostatic Precipitator. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and the word “DANGER”, “WARNING”, or “CAUTION”.
Parker Hannifin representative. The purpose of this manual is to provide the proper operating and maintenance guidelines for the SHM system supplied by Parker Hannifin. As you review this manual, refer to Figure 1 for assistance in identifying oil mist collector parts.
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models 2.2 Equipment Description This section will briefly describe each component in the SHM and its role in the system’s operation. Filter Cabinet Each unit has a filter access door that provides access to the primary filters for service and replacement.
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models 61-10129 61-10129 Figure 1D SHM-08C Advanced Equipment Description 2.3 Principal Of Operation The purpose of the SHM is to collect fugitive mist generated by various industrial processes during operation. The collected contaminate is drained off of the coalescing filters into the sump below. The sump is attached to a drain system of the customers choice for recycling or disposal.
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models 3. Installation 3.1 Inspection And Off Loading As soon as your equipment arrives, it should be carefully inspected to make certain that it is in good condition and that all items listed on the packing list have been received. Even though the items are carefully loaded and tied down at the time of shipment, it is possible for them to be damaged or become dislodged in transit.
Page 10
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models 61-10131 FIGURE 2 Figure 2 SHM Weights and Lifting Info SHM Weights and Lifting Info...
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models 3.4 Mechanical Installation CRUSH HAZARD Use adequate safety measures when lifting and assembling any heavy components. Consult your plant safety personnel for recommendations. Connect lifting slings and spreader bars to lifting lugs with clevis pins.
Page 12
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models Metal Truss Supported Ceilings. Figure 3A shows an example of a SHM unit suspended from a metal truss supported ceiling. Customer should take care to determine that the truss will be sufficient to support the weight.
Page 13
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models 61-10127 Figure 3C Wall Mounted Unit Wall mounted units are mounted to the side of the customers machine or a nearby wall. Refer to figure 3B above for proper mounting locations and instructions. Various wall mount brackets are offered and should be selected based on the desired orientation of the unit when fully assembled.
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models 3.5 Electrical Connection The SHM is available with various controls configurations. Refer to the section headings below and follow the section instructions that best align with your specific unit. The SHM customer electrical connections are located on the left side of the unit in most instances as shown in Figure 1B/D.
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models Description of Wiring Diagram Appendix Basic Units Remote Panel Touch Controls Advanced Unit W/ Remote Controls Transformer 575:480 Table 2 Wiring Diagrams 3.5.1 Electrical Supply Power The main power supply is connected to the SHM unit through a customer sourced, sealed, 1/2" conduit connector that can be installed into the 7/8"...
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models 3.5.3 Advanced Option Unit The main control panel for the advanced SHM unit is a touchscreen interface located remotely in an auxiliary enclosure (refer to section 3.5.4) that operates the blower. The touchscreen control panel is powered by 24V DC. Refer to Section 4 of this manual for operation of the touchscreen.
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models 3.6.1 Installation Procedure For After-Filter Center the filter atop the unit directly over the perforated cutout in the top panel. The hold-down brackets are to be placed on top the filters as shown in Figure 5 balloon #1 and secured down with all-thread rods, washers and nuts.
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models 3.7 Drains All SHM units are supplied with 1-1⁄2˝ FNPT drain connections. A drain trap or similar is to be utilized to prevent air from being sucked up through the drain when unit is running. NOTES: Main drain line should be sufficiently sloped and vented.
Figure 6. The home display screen shown in Figure 7 will be displayed www.parker.com during operation. This will act as your status screen and be your Figure 6 gateway to other screens.
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models 4.3.2 Standard Format The icon key, Table 3, outlines the various icons that are used on the screen for various reasons and may indicate status or conditions. The Home, Settings, and Information icons are shown at the bottom of most screens and will take you directly to their associated screens.
PLC/touchscreen. This should only be done before Information Screen: Information Screen: the unit is shipped, by a technician during install, or with guidance from a Parker Hannifin representative. Program: Program: Version 2.6.2 Version 2.6.2...
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models Figure 9 4.3.4 Auto-Flow Screen When Auto-Flow is installed and activated the blower screen will look like Figure 11. Refer to section 4.3.6 to activate the Auto-Flow Se Auto-Flow option and to make adjustments to your flow target. 800 CFM The Auto-Flow blower screen will show the target flow, the actual Figure 12...
Page 24
Figure 14 SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models When the units selection is made on the Customer Settings screen, you will see the screen as shown on Figure 15. The operator can select the Service settings shown here. Each of the selection will allow the operator to see the health of the unit.
Page 25
SMOGHOG Media Mist Collector SHM-05C & SHM-08C Models Figure 17 The Auto-Flow Settings screen can be selected in the Locked Settings group on the Customer settings screen. Auto-Flow is an option that is selected at time of order and loaded into the SHM at the factory.
SHM and its associated components, is the best possible method to ensure the unit stays in proper working order. Refer to Section 6 for troubleshooting guide to correct any problems that may occur with your oil mist collection unit. If the problem or condition continues, contact Parker Hannifin customer service for assistance. Task...
When filter pressure drop reaches the point where they can no longer provide the desired airflow to capture and control the contaminant, the filters need to be replaced. To order filters, contact your Parker Hannifin sales representative. Identify your filter part number from your sales order, your unit nameplate, or the inside cover of this manual.
6. Troubleshooting Guide Use the troubleshooting guide to correct any problems that occur with your oil mist collection unit. If the problem or condition continues, contact the Parker Hannifin customer service office. All electrical/mechanical troubleshooting should be performed by a qualified electrician/ maintenance individual familiar with Parker Hannifin equipment.
SHM-05C & SHM-08C Models 7. Replacement Parts To order replacement parts, refer to Figure 22. Order through your local Parker Hannifin representative or contact Parker Hannifin at 1-800-252-4647. Please have the unit model number, serial number (from component access door) and part numbers available when ordering.
Page 35
Quality Department for verification of failure mode. The claims will EQUIPMENT OR SERVICE, STORAGE CHARGES, OR ANY be paid in the form of a credit to the customer’s account. Parker OTHER SPECIAL, INCIDENTAL OR CONSEQUENTIAL reserves the right to withdraw any quotation or proposal or reject DAMAGES CAUSED BY THE USE, MISUSE OR INABILITY any purchase order without liability.