Cautions, Warnings, and Regulatory Information..................3 Introduction..............................4 Inspecting the contents of shipment..............................4 Overview.................................5 City circuit card specifications................................6 Mounting the city circuit card inside the cabinet..................7 Communications and power connection....................8 City card configuration..........................9 Configuring the city circuit card................................9 Setting P6.......................................9 Configuring disconnect settings of the city circuit card........................
Product operation and reliability depend upon proper installation. DO NOT INSTALL ANY SIMPLEX™ PRODUCT THAT APPEARS DAMAGED Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately file a claim with the carrier and notify an authorized Simplex product supplier.
This publication describes the installation procedure for the City Circuit Card with Disconnect Switch 2050-9909. Inspecting the contents of shipment Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately file a claim with the carrier and notify your local Simplex product supplier.
2050 and 2250 Foundation Series Fire Alarm Control Unit City Circuit Card Installation Guide 3 Overview The 2050-9909 city circuit card is used to annunciate alarms and other urgent indications to remote facilities. When the 2050 or 2250 control unit goes into alarm, the city card circuits are activated and annunciation immediately occurs at the remote facility. Reverse polarity modules or local energy modules, used for reaching the Public Service Fire Communications Center, receive annunciations at the remote site.
2050 and 2250 Foundation Series Fire Alarm Control Unit City Circuit Card Installation Guide City circuit card specifications Table 1: City circuit card specifications Electrical specifications Input voltage 20 VDC to 32 VDC at 37 mA max. Current 20 mA at 24 VDC, nominal 36 mA at 24 VDC, both relays on City output voltage ±...
2050 and 2250 Foundation Series Fire Alarm Control Unit City Circuit Card Installation Guide 4 Mounting the city circuit card inside the cabinet Complete the following steps: Remove the AC power at the breaker from the control unit. Open the cabinet and disconnect the battery. Locate the city circuit card in the enclosure by using the locating features provided.
2050 and 2250 Foundation Series Fire Alarm Control Unit City Circuit Card Installation Guide 5 Communications and power connection The city circuit card comes with a power and communication harness. You can use this harness for interfacing the city circuit card with the 2050 or 2250 control unit.
2050 and 2250 Foundation Series Fire Alarm Control Unit City Circuit Card Installation Guide 6 City card configuration Configuring the city circuit card Use the information in Table 2 and Setting P6 to set the jumper positions for reverse polarity and local energy operations. Table 2: Jumper positions Reverse polarity Local energy...
Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. Simplex, and the product names listed in this material are marks or registered marks.