Assembly
Attention! Never operate the device if the nozzle seal is either damaged or
missing. If the nozzle seal is either missing or damaged liquids can enter
the device and increase the risk of an electric shock.
1) Check the nozzle seal (fig. 17, 4) in the nozzle.
2) Screw the union nut (Fig. 18, 2) onto the gun and tighten it.
Tighten the union nut (Fig. 18, 2) fully so that no paint is able to penetrate
the device.
3) Engage the air cap (Fig. 19, 1) with the union nut. Check if the air cap has properly
locked into place on both sides. (Fig. 19, 2)
4) Place the container seal from below on the suction tube and slide it over the collar,
while turning the container seal slightly.
5) Insert the suction tube with container seal in the gun body.
In order to mount the gun more easily apply lubricating grease (enclosed) liberally
to the O-ring at the gun front part. (Fig. 23, 3)

20. Cleaning the Standard spray attachment

CAUTION!
Never clean seals, diaphragm and nozzle or air holes of the spray gun with
metal objects.The ventilation hose and diaphragm are only solvent-resistant
to a limited extent. Do not immerse in solvent, only wipe.
6) The unit may only be operated with an integer diaphragm (Fig. 15, 3). If any
paint has penetrated to the ventilation hose, check and clean the membrane (see the
Maintenance chapter).
7) Unscrew the union nut and remove the air cap and nozzle. (Fig. 20)
Clean the air cap, nozzle seal and nozzle with a brush and solvent or water.
8) Clean the outside of the spray gun and container with a cloth soaked in solvent or
water.
9) Assemble the parts again (see "Assembly").
Assembly
Attention! Never operate the device if the nozzle seal is either damaged or
missing. If the nozzle seal is either missing or damaged liquids can enter
the device and increase the risk of an electric shock.
1) Push the nozzle seal (fig. 21, 1) over the needle (3); the groove (slot) should point
towards you.
2) Put the nozzle (fig. 21, 2) onto the gun body and find the correct position by turning it.
3) Put the air cap onto the nozzle and tighten it using the union nut.
4) Place the container seal from below on the suction tube and slide it over the collar,
while turning the container seal slightly.