Over Load Alarm; Data Logger - INTEGRA Metering aquastream LoRa User Manual

Modular system for mechanical water meters
Table of Contents

Advertisement

6.3.4

Over Load Alarm

The module analyses the instantaneous flow rate. If it detects a flow rate higher than the threshold value
(3125 l/h for DN15) for more than 30min, the alarm is activated.
The alarm can only be reset via NFC using the ParamApp application.
The factory setting is defined as following:
DN15
DN20
3 125 l/h
5 000 l/h
6.3.5

Data Logger

The aquastream® modules are equipped with a memory for storing values automatically.
It allows the management of the following histories:
-
Start and end of event and alarms (date + event type)
-
Index values (index and date) : yearly, monthly, daily and hourly
The capacity of the Datalogger memory are the following:
Version
Capacity
AQS-MB
12 monthly values (end of month)
16 yearly values (end of year) – 48 monthly values (end of month) – 460 daily values
AQS-MBOC
(end of day) – 24 hourly values (last 24 hours)
16 yearly values (end of year) – 48 monthly values (end of month) – 460 daily values
AQS-W8
(end of day) – 24 hourly values (last 24 hours)
16 yearly values (end of year) – 48 monthly values (end of month) – 460 daily values
AQS-L8
(end of day) – 24 hourly values (last 24 hours)
These values can be read and downloaded with ParamApp.
18
DN25
DN32
7 875 l/h
12 500 l/h
DN40
DN50
20 000 l/h
31 250 l/h

Advertisement

Table of Contents
loading

Table of Contents