The event type Message, in module 1113, allows us to activate during the message the out1-OUT8 relay outputs, A
new Outputs tab appears, with the parameter:
Relay Outputs: You choose whether to enable or disable each relay OUTX output. If, in a simple installation, each
output is wired to a zone amplifier, it allows you to select whether or not the warning will sound in an area:
contact NO to PIN OUT output of the 1113, and COM contact to PIN input of the amplifier.
A second module 1111 for ambient music can be included in the installation and wired so that the warning
interrupts the music in the selected areas: NC contact towards PIN OUT output of module 1111, contact NO
towards PIN OUT output of 1113, and COM contact towards PIN input of the amplifier.
37.