LCD/Inverter Power Select
JP2 is used to select the power level of LVDS LCD inverter connector.
Chapter 2 Hardware Installation
Chapter 2
1
2
3
JP2
1-2 On:
+12V (default)
1
2
3
2-3 On: +5V
18
Panel Power Select
JP7 is used to select the power supplied with the LCD panel.
Important:
Before powering-on the system, make sure that the power settings of JP7 match the
LCD panel's specification. Selecting the incorrect voltage will seriously damage the
LCD panel.
2 4
6
JP7
1 3 5
1-2 On: +12V
2 4
6
1 3 5
3-4 On: +5V
2 4
6
1 3 5
5-6 On: +3.3V
(default)
www.dfi .com